Compliance With Regulations; Emc Requirements; Protection Class; Contamination Class - Gewiss R-EVolution Parking+ GW68105 Manuel D'installation Et Usage

Parking+
Masquer les pouces Voir aussi pour R-EVolution Parking+ GW68105:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Gewiss
Bottom trim
If the underground support element is not requested, it is possible to install the bottom trim individually. This trim
is a metal surface that supports the unit.

2.2. Compliance with regulations

CE marking
CE marking is mandatory for the sale of any product within the European Union, without prejudice to standards or
laws. These charging stations have the CE marking because of their compliance with the following directives:
Low Voltage Directive 2014/35/EU.
Electromagnetic Compatibility Directive 2014/30/EU.
To comply with each directive, compliance with the parts applicable to our units of the appropriate harmonized
standards is sufficient.
Low Voltage Directive
These charging stations sufficiently comply with this directive by means of compliance with the applicable parts of
harmonized standard EN 61851 Electric vehicle conductive charging system.
Electromagnetic Compatibility Directive
These charging stations sufficiently comply with this directive by means of compliance with the applicable parts of
harmonized standards:
EN 61000-6-2 Electromagnetic Compatibility. Part 6-1: Generic standards - Immunity for residential,
commercial and light-industrial environments.
EN 61000-6-3 Electromagnetic Compatibility. Part 6-3: Generic standards - Emission for residential,
commercial and light-industrial environments.
Compliance with these standards calls for compliance with limits and procedures in other standards of the same
series.

2.3. EMC requirements

These charging stations have the necessary filtering elements to comply with EMC requirements for domestic
applications in order to prevent disturbances in other equipment outside the installation.

2.4. Protection class

These charging stations meet IP54 protection class against external agents.
This unit is designed to be used indoors and outdoors.

2.5. Contamination class

The pollution class for which the charging stations have been designed is grade PD3.
8
ABA2022IQM01_ - 7.55.4.183.9 - Installation and Operation Manual
Unit description

Publicité

Table des Matières
loading

Table des Matières