Communication Accessories; Local Communication; R-Evolution Parking - Gewiss R-EVolution Parking+ GW68105 Manuel D'installation Et Usage

Parking+
Masquer les pouces Voir aussi pour R-EVolution Parking+ GW68105:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Gewiss

8. Communication accessories

These charging stations have a local RS-485 data bus that enables interconnection between the stations.
All the charging stations can be accessed either locally or remotely. For remote connection they use an external
modem located in the installation or a modem supplied in the charging station if requested upon placing the order.
This section explains the wiring process for local connection, whereby this type of connection is available as
standard.

8.1. Local communication

8.1.1. R-EVolution Parking+

Follow the instructions below to complete the local connection:
1.
Connect the communication ring.
First station
The JP1 jumper for control cards comes uninstalled. In all intermediate stations, the communication
ring must remain uninstalled, but must be installed in the two ends.
24
Intermediate station
ABA2022IQM01_ - 7.55.4.183.9 - Installation and Operation Manual
Communication accessories
Final station

Publicité

Table des Matières
loading

Table des Matières