General Technical Data; Technical Data Table; Instructions For Installation; Installation - Lotus PCIT-64ET Instructions Pour L'installation Et L'emploi

Plan de cuisson à induction triphasé
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

The data plate is on the front (see diagram in electric connection item) and has all the data necessary for the connection.
When fitting, the appliance must be leveled using a spirit level; slight differences of level can be adjusted by screwing
or unscrewing the adjustable feet. The main switch or the socket must be near the appliance and easily accessible.
It is advisable to place the appliance under an extractor hood so that steam is extracted rapidly. If the appliance is placed
near walls, dividing panels, kitchen furniture, decorative finishes, etc., these should be in flameproof material; otherwise
it is necessary to cover them with non-flammable material.
Above all, it is necessary to ensure that fire prevention standards are observed.
Always comply with the following points during installation:
-
Ensure that mains voltage complies with the voltage indicated on the specification table of the
appliance
-
All electrical installations must comply with local standards. All standards issued by national electrical authorities
must be complied with.
-
When circuit breakers are used, they must be suitable for a minimum of 30 mA.
-
Avoid obstruction of air intakes or outlets with objects (fabric, walls, etc).
-
Keep hot air off of the induction appliance (for example when several appliances are next to one another, or behind one
another, or when an appliance is separated by a separate air duct.
-
The induction appliance must not be placed near or on hot surfaces.
-The appliance is equipped with a filter. Regardless of this filter, make sure that grease from other
activities do not get onto the induction appliance (for example from nearby fryers or hot plates).
GB

GENERAL TECHNICAL DATA

Minimal pan diameter:
Relative humidity:
Operation Ambient temperature:
Voltage tolerance:
Supply frequency:

TECHNICAL DATA TABLE

MODELS
DIMENSIONS cm
POWER SUPPLY
MAXIMUM ABSORPTION A
MAXIMUM POWER kW
POWER SUPPLY CABLE

INSTRUCTIONS FOR INSTALLATION

INSTALLATION

IE
120 mm
10% to 90% non-condensing
0°C ÷ 40°C
-10% ÷ +6%
50 – 60 Hz
PCIT-64ET
PCIWT-64ET
40x60x28 h
40x60x28 h
400V/3 50/60Hz 400V/3 50/60Hz
7,2 A
7,2 A
5 kW
5 kW
4x1,5 mm²
4x1,5 mm²
40

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pciwt-64etPcit-64etd

Table des Matières