1. Connect one end of the red battery cable to the
POSITIVE (+) battery terminal (A) on the weak
battery.
B
A
2. Connect the other end of the red battery cable to the
POSITIVE (+) battery terminal (B) on the charged
battery.
WARNING: Do not let the ends of the
red battery cable touch the chassis. This
will cause a short circuit.
3. Connect one end of the black battery cable to the
NEGATIVE (-) battery terminal (C) on the charged
battery.
4. Connect the other end of the black battery cable to a
CHASSIS GROUND (D), away from the fuel tank
and the battery.
To remove the jumper cables
Note: Remove the jumper cables in the opposite
sequence to how you connect them.
1. Remove the BLACK cable from the chassis.
2. Remove the BLACK cable from the fully charged
battery.
3. Remove the RED cable from the 2 batteries.
Regeneration
To decrease the exhaust emissions, the diesel engine
has a diesel particulate filter (DPF) that collects
unwanted material from the exhaust. The concentration
of unwanted material in the diesel particulate filter
increases during operation and it is necessary to clean
the diesel particulate filter regularly. The procedure to
clean the diesel particulate filter, a DPF regeneration, is
a fully automatic procedure that is started by the
operator and controlled by the engine control unit. There
are different modes of regeneration:
Stationary regeneration standby
36
C
D
Stationary regeneration
Regeneration back up mode
Recovery regeneration
Stationary regeneration standby
When these warning symbols show on the display, the
engine is in regeneration standby.
The power output of the engine is decreased. During the
first 2 hours, the power output is decreased to 85% and
then to 50%. After 8 hours, or when the soot load
increases to more than 11.5 g/l, the maximum engine
speed is decreased to 1500 rpm.
It is necessary to do a stationary regeneration in the
shortest time possible after the warning symbols show.
Stationary regeneration
Approximately 30 minutes are necessary to do a
stationary regeneration. Refer to the operator's manual
for the control panel for information on how to do the
stationary regeneration.
Regeneration backup mode
When these warning symbols show on the display, the
engine is in regeneration backup mode.
The power output of the engine is decreased to 50%.
The maximum engine speed is decreased to low idle
speed. It is necessary to do a recovery regeneration for
the engine to operate correctly again.
Recovery regeneration
Approximately 3 hours are necessary to do a recovery
regeneration. Refer to the operator's manual for the
control panel for information on how to do the recovery
regeneration.
Note: The operator can do a recovery regeneration from
the control panel on all products with a production date
from January 1 2019. For engines with a production date
before January 1 2019, an ECU software update is
necessary before the operator can do a recovery
regeneration from the control panel. If the update of the
ECU software is not done, the Yanmar servicing tool
SmartAssist must be used to do a recovery
regeneration. Speak to your Husqvarna service center
for more information.