Introduction; Specifications, Appliance Dimensions & Installation Codes - Sierra Flame PALISADE-36 Instructions D'installation Et D'utilisation

Table des Matières

Publicité

1.0 INTRODUCTION

1.1 SPECIFICATIONS
TABLE 1
ITEM
INPUT: Hi
INPUT: Lo
MANIFOLD PRESSURE: Hi
COLLECTEUR DE PRESSION: FORT
MANIFOLD PRESSURE: Lo
COLLECTEUR DE PRESSION:
FAIBLE
GAS INLET SUPPLY PRESSURE:
ENTREE DE PRESSION
ORIFICE SIZE: @ 0-2000'
FORMAT D'ORIFICE:
VALVE ORIFICE @ 0-2000'
SOUPANGE D'ORIFICE:
AIR SHUTTER
VOLET DE L'AIR
CONTROL VALVE TYPE:
TYPE DE SOUPAPE
VENTING
ÉVACUATION
FAN
VENTILATEUR
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING
CET APPAREIL DOIT ÊTRE UTILISÉ UNIQUEMENT AVEC LE TYPE DE GAZ INDIQUÉ SUR LA
THIS APPLIANCE IS CERTIFIED FOR USE IN A BEDROOM / BATHROOM APPLICATION
CET APPAREIL EST CERTIFIÉ POUR UTILISATION DANS UNE APPLICATION CHAMBRE /
NATURAL GAS (NG)
20,000 Btu/hr (5.861 kW)
13,000 Btu/hr (3.81 kW)
3.5" w.c. (0.87 kPa)
1.7" w.c. (0.42 kPa)
Minimum: 5.0" w.c. (1.2 kPa)
Maximum: 13.5" w.c. (3.4 kPa)
# 44 DMS
# 51 DMS
OPEN 1/8"min
(3.175mm)
Skytech AF-40004
Robertshaw
2-ply aluminum vent, Selkirk,
Duravent, Metal-Fab, ICC or Security
Venting
Variable Speed (115 Volt)
PLATE.
PLAQUE SIGNALÉTIQUE.
SALLE DE BAIN
PROPANE (LP)
19,500 Btu/hr (5.71 kW)
13,500 (3.96 kW)
10.0" w.c. (2.49 kPa)
6.4" w.c. (1.59 kPa)
Minimum: 7.0" w.c. (1.74 kPa)
Maximum: 13.5 w.c. (3.4 kPa)
#56 DIMS
#60 DIMS
FULLY OPEN
Skytech AF-40004
Robertshaw
2-ply aluminum vent, Selkirk
Duravent, Metal-Fab, ICC or Security
Venting
Variable Speed (115 Volt)
Page 6 of 60