VENT RESTRICTOR INSTALLATION
VENT RESTRICTOR
To fasten the Restrictor Plate to the ceiling of the firebox:
1/. Remove the 2 screws that are in place
2/. Remove portion of restrictor for your correct air flow
3/. Fasten Restrictor Plate back in place.
VENT
RESTRICTOR INSTALLATION (continued)
The restrictor plate is included loose in the bottom of your fireplace. The restrictor plate comes factory
set at 60% with 3 portions. For 40% restriction, break off one side of the restrictor plate. For 20%
restriction, break off both sides of the restrictor plate. For 0 restriction do not install.
ALLOWING THE VENT PIPE TO SLOPE DOWN TOWARDS THE VENT TERMINATION COULD
CAUSE POOR COMBUSTION AND/OR HIGH TEMPERATURES THAT MAY PRESENT A FIRE
PERMETTRE LA tuyau de ventilation vers descendent vers la sortie de ventilation POURRAIT
PROVOQUER une mauvaise combustion et / ou de températures élevées qui peuvent présenter
Vent Configuration Restrictor Size
Factory set
Remove 1 side
Remove 2 sides
No restrictor
20% restrictor
40% restrictor
60% restrictor
HAZARD.
des risques d'incendie.
60%
40%
20%
0 – 10'
10 – 18'
18 – 26'
26 – 34'
Page 29 of 60