Grizzly GP 3032 Inox Traduction De La Notice D'utilisation Originale page 21

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22
Troubleshooting
Problem
Pump does not
start
Pump does not
supply
Fluid quantity
insufficient
Pump switches
off after short
run time
Possible Cause
Mains voltage missing
Pump is not switched on.
On/off switch (
defective
Pump chamber without water
Pump, suction line or suction
filter blocked
Suction line is leaky or dam-
aged
Suction height too high
Pumping capacity reduced due
to very dirty or abrasive admix-
tures of water
Engine protection switches the
pump off due to very strong
water contamination.
Water temperature is too high,
engine protection switches the
device off.
Error correction
Check the socket, mains connec-
tion cable, line, mains plug, repair
to be carried out by qualified elec-
trician if necessary.
Turn pump on at
on/off switch (
repair to be carried out by quali-
7) may be
fied electrician if necessary.
Fill water
Clean pump
Check the suction line and seal or
replace if necessary
Check suction height
Clean pump
Switch device off and pull power
plug.
The pump is designed exclusively
for the supply of clarified water
and rain water.
Pay attention to maximum tem-
perature of 35 °C!
GB
7)
21

Publicité

Table des Matières
loading

Table des Matières