Signal Conditioning - HBM PAD4002A Manuel D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Structure and mode of operation
FMD
ASF
A
Filter
D
RUN
BRK
12
3.2

Signal conditioning

SZA
ICR
SFA
Samp-
Working
ling
standard
rate
calibration
Dosing control
Fig. 3.2
Signal conditioning
Digitization is followed by filtering, using digital filters ad­
justed by the software. The command ICR changes the
output rate (measured values per second).
In the working standard calibration of the electronics (on
delivery), 0 mV/V corresponds to zero and the maximum
capacity is either 1,000,000 digits (NOV≠0), or
5,120,000 digits (NOV=0). The two parameters LDW and
LWT give you the opportunity to adapt the characteristic
curve to meet your requirements (scale curve) and you
can use the NOV command to standardize the measured
values to the required scaling value (e.g. 3000 d). De­
tailed information can be found in the command docu­
mentation and in the Online Help for the PanelX pro­
gram.
You also have the opportunity to
S switch from gross to net signals,
A4243-1.0 HBM: public
NOV, RSN
LDW, LWT
LIC
User-defined
Lineari−
scaling
zation
Coarse Flow
Fine Flow
Ready
Alarm
Gross
meas.
value
TAV, TAS
Net
meas.
Tare
value
PVA
Extreme
Min/
values
Max
IMD
Trigger/
Trigger
Stop
LIV
Limit
Limit
values
values
PAD4002A

Publicité

Table des Matières
loading

Table des Matières