Anleitung_BT_PG_5500_2_D_SPK1__ 24.07.13 14:10 Seite 18
GB
7.6 Ordering replacement parts:
Please quote the following data when ordering
replacement parts:
Type of machine
n
Article number of the machine
n
Identification number of the machine
n
Replacement part number of the part required
n
For our latest prices and information please go to
www.isc-gmbh.info
Fault
Engine does not start
Generator has too little or no
voltage
18
8. Disposal and recycling
The unit is supplied in packaging to prevent its being
damaged in transit. This packaging is raw material
and can therefore be reused or can be returned to
the raw material system.
The unit and its accessories are made of various
types of material, such as metal and plastic.
Defective components must be disposed of as
special waste. Ask your dealer or your local council.
Cause
Automatic oil cut-out has not
responded
Spark plug fouled
No fuel
Controller or capacitor defective
Overcurrent circuit-breaker has
triggered
Air filter dirty
Remedy
Check oil level, top up engine oil
Clean or replace spark plug
(electrode spacing 0.6 mm)
Refuel / have the petrol cock
checked
Contact your dealer
Actuate the circuit-breaker and
reduce the consumers
Clean or replace the filter