NB-IoT PULSE - Guide utilisateur / User guide version V1.0.0
Example :
Register
Value encoding
S320
Hexadecimal
S322
Hexadecimal
S325
Decimal
S328
Decimal
S329
Decimal
S330
Decimal
S331
Decimal
In this example, all the periods during which the flow rate on the channel A is less than 10 pulses /
hour are considered as periods of zero flow. If the total daily number of zero flow periods is less than 3
then it is considered that there is a leak on the channel A.
2.3. Operation of the LEDs
Mode
Product in Park mode
Magnet detection process (1 to 6
seconds)
Product start (after detection of
the magnet)
Switching to the Command mode Continuously lit
Product faulty (return to factory) Fixed ON
Value
Result
0x39
Channel A :
•
Activated
•
Meter other than gas
•
Tamper input activated
Channel B :
•
Activated
•
Gas meter
•
Tamper input disabled
0x57
Anti-bounce :
•
Channel A = 500ms
•
Channel B = 100ms
60
Flow calculation period (channels A and B) = 60min
10
Leak threshold (channel A) = 10 pulses par hour
0
Leak threshold (channel B) = 0 pulse par hour
3
Daily periods number under the leak threshold (channel A)
= 3
5
Daily periods number under the leak threshold (channel B)
= 5
LED red state
OFF
OFF
OFF
LED green state
OFF
ON from detection of the mag-
net up to a maximum of 1
second
Rapid flashing 6 cycles, 100 ms
ON / 100 ms OFF
Continuously lit
FR
EN
Page
51