NB-IoT PULSE - Guide utilisateur / User guide version V1.0.0
2.2. Application operation
2.2.1
Periodic transmission
The product allows the measurement and the periodic transmission of the values of the sensors accord-
ing to the following diagram:
FR
EN
No
reached
Number of
savings be-
fore send-
ing =1?
Send frame 0x46
Eg:
Register Value encoding
S301
Decimal
S321
Decimal
S320
Hexadecimal
S322
Hexadecimal
N.B: for a periodical transmission without historisation of the data, S301 must be egal to 1.
Product in
standby
Period
?
Yes
No
See paragraph about periodical
Yes
transmission with historic
Value
1
43200
0x39
0x57
Detected
No
and validat-
ed pulse
?
Yes
Counting
of the impulse
Result
Number of historisation (savings) to be done before
sending
Period of historisation/saving of the data (43200x 2
seconds = 24h).
Channel A :
•
Activated
•
Meter other than gas
•
Tamper input activated
Channel B :
•
Activated
•
Gas meter
•
Tamper input disabled
Anti-rebound :
•
Channel A = 500ms
•
Channel B = 100ms
The settings associated with this
mode of operation are:
•
Transmission frequency (register
S301)
•
Historisation period of the data
(register S321)
•
Enabling and Configuring inputs
(register S320)
•
Anti-bounce timer period (regis-
ters S322)
A complete list of the registers can
be found in paragraph 3.4.
Page
44
of 56