Anleitung_RT_AC_250_24_10_SPK1:_
GB
3. Scope of use
The compressor is designed for generating
compressed air for tools operated by compressed
air.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
The machine is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the
manufacturer will be liable for any damage or injuries
of any kind caused as a result of this.
4. Technical data
Power supply:
Motor rating in kW/HP:
Operating mode
Compressor speed in rpm:
Operating pressure in bar:
Pressure vessel volume in litre:
Theoretical intake rate in l/min.:
Sound power level L
in dB:
WA
Sound pressure level L
in dB:
pA
Protection type:
Machine weight in kg:
Operating mode S3 - 50% - 10min: S3 = Intermittent
mode without influencing the starting process. This
means that during a period of 10 min the max.
operating time is 50% (5 min).
5. Points to note when setting up the
compressor
Examine the machine for signs of transit
damage. Report any damage immediately to the
company which delivered the compressor.
The compressor should be set up near the
working consumer.
Avoid long air lines and long supply lines
(extensions).
Make sure the intake air is dry and dust-free.
14
07.08.2008
9:03 Uhr
Do not set up the compressor in damp or wet
rooms.
The compressor may only be used in suitable
rooms (with good ventilation and an ambient
temperature from +5°C to +40°C). There must be
no dust, acids, vapors, explosive gases or
inflammable gases in the room.
The compressor is designed to be used in dry
rooms. It is prohibited to use the compressor in
areas where work is conducted with sprayed
water.
The oil level in the compressor pump has to be
checked before putting the equipment into
operation.
6. Assembly and starting
Important!
You must fully assemble the appliance before
using it for the first time.
230 ~ 50 Hz
6.1 Fitting the wheels (3)
1.6/2.2
Fit the supplied wheels as shown in Fig. 5.
S3 50% 10 min
6.2 Fitting the supporting feet (4)
2850
Fit the supplied supporting feet (4) as shown in Fig.
10
6.
24
6.3. Fitting the air filter (1)
250
Remove the transportation stop with a screwdriver or
92.4
similar and screw the air filter (1) securely to the
equipment. (Fig. 7)
72.4
IP 20
6.4. Replacing the oil sealing plug (14)
26
Remove the transportation cover from the oil filler
opening with a screwdriver and insert the supplied oil
dipstick (14) into the oil filler opening. (Fig. 8)
6.5 Fitting the transport handle (9)
Screw the transport handle (9) to the compressor as
shown in Figures 9 to 10.
6.6 Voltage
The compressor is equipped with a mains cable with
shock-proof plug. This can be connected to any
230V ~ 50Hz shock-proof socket which is protected
by a 16 A fuse. Before you use the machine, make
sure that the mains voltage complies with the
specifications on the rating plate. Long supply
cables, extensions, cable reels etc. cause a drop in
voltage and can impede motor start-up. In the case
of low temperatures below +5°C, motor start-up is
jeopardized as a result of stiffness.
Seite 14