Télécharger Imprimer la page

DeLonghi PAC N110EC Mode D'emploi page 8

Publicité

Les langues disponibles

Les langues disponibles

TURNING THE APPLIANCE ON
Before plugging the appliance check the caps on the back
of the unit are correctly inserted and screwed on the
drainage 10.
plug into an outlet. Two lines appear on the display indicating
that the appliance is in stand-by. Press the ON/STAND-BY
button (A). When turned on, the air conditioner starts operating
in the same mode as when it was turned off. Press the MODE
button (B) until the light corresponding to the desired mode
lights up:
light (O): air-conditioning mode
light (P): dehumidifying mode
light (N): fan mode
AIR CONDITIONING MODE
Ideal for hot muggy weather when you need to cool and
dehumidify the room.
The display shows the inner temperature: the light (S) turns
on.
To modify the set temperature, push the (E) or (F) button to
reach the desired temperature. The (T) light turns on and the
(S) light turns off. (To change from °f to °C or viceversa, press
for few seconds both button E and F).
After 15 seconds, the inner temperature is shown on the
display.
The (S) light turns on.
You can adjust the temperature only in air conditioning mode.
Then select the fan speed by pressing the FAN button (C) until
the light corresponding to the required fan speed lights up:
BOOST:
the air conditioner operates at maximum to achieve
the target temperature as rapidly as possible
ECONO:
reduces noise levels while maintaining a
comfortable temperature
qUIET:
for silent operation
The most suitable temperature for the room during the summer
varies from 75°F to 81°F (24 to 27°C). You are recommended,
however, not to set a temperature much below the outdoor
temperature.
FAN MODE
Adjust fan speed by pressing the FAN button (C) as described
for the air-conditioning mode.
Remember that the higher the speed, the more air is filtered. If
you select "qUIET" speed, less air is filtered but the appliance
is also less noisy.
DEHUMIDIFYING MODE
Ideal for reducing the humidity in a room without lowering or
raising the temperature (spring or autumn, damp rooms, rainy
spells, etc). When the dehumidifying mode is selected, the
light (P) comes on. At the same time, the "qUIET" fan speed
light (M) comes on. In this mode, other speeds cannot be
selected.
PROGRAMMING THE TIMER
The timer can be used to delay appliance start up or shut down.
This avoids wasting electricity by optimising operating periods.
How to programme delayed start up
plug the appliance into a mains socket and press the on/
OFF button (A), then select the required operating mode
and other settings (temperature, fan speed, etc).
press the on/off button (A) again to place the appliance
in standby mode.
press the timer button (D). The timer light " H" flashes.
Use the + (E) or - (F) buttons to set the number of hours
delay before the appliance comes on. T he time increases or
decreases in steps of one hour.
The indicator light (H) flashes until the appliance starts up.
You can set the appliance to come on with a delay of up to 12
hours. To cancel the timer programme, press the timer button
(D) again. light (H) stops flashing.
How to programme delayed shut down
Delayed shut down can be programmed in any operating
mode (air conditioning / fan/ dehumidifying).
press the timer button (D). The timer light " H" flashes.
Use the + (E) or - (F) buttons to set the number of hours
delay before the appliance goes off.
The time increases or decreases in steps of one hour.
The light (H) flashes until the appliance turns off as
programmed. At the set time, the air conditioner shuts down
and remains in standby. To cancel the timer programme, press
the timer button (D) again.
light (H) stops flashing.
MODELS WITH REMOTE CONTROL
point the remote
control at the
receiver on the
air conditioner.
The
remote
control must be
no more than 16,4 ft (5 meters) away from the appliance
8
Operation
en

Publicité

loading