Please note: that the Aduro 9-5 Lux must be installed on a floor with the adequate load-bearing capacity. If the
existing construction does not meet this requirement, appropriate adaptation measures must be taken (e.g. a load-
distributing plate).
If the wood burning stove is to be placed close to flammable material, such as a wooden floor or carpet, it must be
placed on a non-flammable base. The floor plate should extend for at least 30 cm in front of the wood burning
stove, and 15 cm on each side – measured from the combustion chamber opening.
2.2 Supply of combustion air
When a stove is installed in a room, the demand for air supply in the room raises. See point 3.9. Air from outside
can be provided through a channel, which is connected to the connecting pipe under the combustion chamber. The
3
amount of air needed for combustion is 25m
/h.
The connecting pipe has an external diameter of 78 mm, to which you need a pipe with a diameter of 80 mm. If the
pipe work is further than 1 m the pipe diameter must be increased to 100 mm and a correspondingly larger wall
valve must be chosen. In warm rooms the channel should be insulated with 30 mm mineral wool covered with a
damp-proof course (plastic). It is important that the lead-in between the pipe and the wall (or floor) is sealed with
jointing compound.
The pipe with external supply of combustion air can be taken out at the bottom of the back side of the stove or
under the stove (see illustration).