2.3 Pipe connection
Aduro 9.3 Lux leaves the factory with the flue outlet mounted on the top. If you require the flue outlet on the back,
remove the round circle from the rear cover at the upper rear of the stove and then exchange the exhaust
connector (located on the top outlet above the stove) with the cover plate (that covers the rear outlet). The inner
heat shield (which is attached to the back plate) has to be removed, since this should not be used when the rear
outlet is chosen. The top outlet is finished with the plate that lies in the ash drawer. A flue pipe with an internal
diameter of 150 mm should be used for Aduro stoves.
2.4 Connection to a brick chimney
If the stove is being connected to a brick chimney, the rear outlet should be used, or a curved flue pipe via the top
outlet. After measurement, a hole is made in the chimney in which the pipe sleeve is placed and fireplace mortar is
used to seal it in place. The stove is placed in position and the flue pipe is put in place. A thin gasket is placed
between the flue pipe and the pipe sleeve to seal the joints. The flue pipe should protrude 5–10 cm into the pipe
sleeve, but must not block the opening in the chimney (see the illustration below).
The wood burning stove can be connected to a chimney to which other heat sources are connected.
Through floor and crawl space
Trough wall