3. BUTTONS
MENU
To select the programming functions
DOWN
To go backward in the selected functions
UP
To go forward in the selected functions
ENTER
To confirm the selected functions
4. REMOTE CONTROL INPUT: Used to connect a simple CA-8 hand controller while the unit is used in
standalone or master/slave mode.
5. SENSITIVITY: Used to adjust the sensitivity of the micro when the unit is used in standalone or
master/slave mode.
6. DMX INPUT/OUTPUT: used for DMX512 linking. Use good quality 3pin XLR M/F balanced cable to link
the units together.
MAIN MENU:
 To select any of the pre-set functions, press the MENU button up to when the required one is shown on
the display.
 Select the function with the ENTER button. The display will blink.
 Use DOWN and UP button to change the mode.
 Once the required mode has been selected, press the ENTER button to select. After 8 seconds the display
will automatically return to the main functions without any change. To go back to the functions without any
change press the MENU button. The main functions are shown on the right.
DMX512 Address Setting
Used to set the starting address in a DMX
setup.
 Press the MENU button until
is shown on
the display.
 Press the ENTER button, the display starts
blinking.
 Use DOWN and UP buttons to change the
DMX512 address.
 Once the correct address shows on the display,
press the ENTER button to save it.
(or automatically return to the main functions
without any change after 8 seconds)
To go back to the functions without any change
press the MENU button again.
Channel Mode
 Press the MENU button until
is shown on
the display.
 Press the ENTER button so the display starts
blinking.
 Use DOWN and UP button to select the
(16 Channel ) or
(8 Channel) mode.
 Once the mode is selected, press the ENTER
button to setup
( or automatically return to the main functions
without any change after 8 seconds. )
To go back to the functions without any change
press the MENU button again.
BRITEQ
®
OPERATION MANUAL
5/64
BT-250W
ENGLISH
Show Mode
Used to choose the Show mode when used in standalone or master/slave mode.
 Press the MENU button until
is showing on the display.
 Press the ENTER button, the display starts blinking.
 Use DOWN and UP buttons to select
4) mode.
 Once the right mode shows on the display, press the ENTER button to save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again.
Show 1 mode- Fixture is placed on the floor. Tilt movement angle 210°.
Show 2 mode-Fixture is fixed under ceiling. Tilt movement angle 90°.
Show 3 mode - Fixture is placed on a podium, in front of the audience
The spot is always projecting to the audience's direction; i.e in front of the stage. Pan movement
angle (left to right to left ): 160°. Tilt movement angle: 90° ( 60° above horizon; 30° below horizon.)
Show 4 mode - Fixture is fixed under ceiling.
The spot is mainly projecting in front of the stage. Pan movement angle ( left to right to left ) :160°.
Tilt movement angle: 90° ( vertically, front 75°; back 15° )
Slave Mode
Used to make the slave unit work in opposite to the master or to work in complete sync.
 Press the MENU button until
is shown on the display.
 Press the ENTER button, the display starts blinking.
 Use DOWN and UP button to select
(normal) or
 Once the mode has been selected, press the ENTER button save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again.
Blackout Mode
Blackout mode: when no DMX-signal is detected, the unit goes in blackout and waits for the DMX-
signal.
No blackout mode: when no DMX-signal is detected, the unit automatically switches to standalone
mode.
 Press the MENU button until
is shown on the display.
 Press the ENTER button, the display starts blinking.
 Use DOWN and UP button to select
(yes blackout) or
 Once the mode has been selected, press the ENTER button to save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again.
Pan Inversion
Normal: Panning movement is not inversed.
Pan inversion: Panning movement is inversed
 Press the MENU button until
is shown on the display.
 Press the ENTER button, the display starts blinking.
 Use DOWN and UP button to select
(normal) or
 Once the mode has been selected, press the ENTER button to save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again.
BRITEQ
®
OPERATION MANUAL
(show 1),
(show 2),
(show 3) or
(2 light show) mode.
(no blackout) mode.
(pan inversion) mode.