LAMP (RE)PLACEMENT
In case of replacement of the lamp or maintenance, do not open the fixture within 10
minutes until the unit cools down after switching off. Always unplug the unit before
servicing! Always use the same type of spare parts (bulbs, fuses, etc.) When replacing
parts, please only genuine spare parts.
 Switch off the main supply and unplug the unit.
 Wait for about 15 minutes until the unit has been cooled down.
 Remove the 4 screws on the backside of the fixture to open the lamp compartment ( A on the picture
below)
 Remove the old lamp (never handle the lamp when it is hot)
Attention! Check the label on the backside of the device or see the technical specifications in this manual
to know which lamp should be used. Never install lamps with a higher wattage!
 Don't touch the bulb with bare hands! This drastically shortens the lifespan of the lamp. If you touched the
lamp, clean it with a cloth and a little denatured alcohol. Wipe the lamp off before installing.
 Put the new lamp back inside the unit. Be sure that the wires don't touch the lamp.
 Fix the 4 screws on the backside of the fixture to close the lamp compartment
 Make sure the lamp is located in the center of the reflector for the best spot. Adjust lamp position by
screws A, B and C, located on the back of the head. ( B on the picture below )
 Done!
OVERHEAD RIGGING
 Important: The installation must be carried
out by qualified service personal only.
Improper installation can result in serious
injuries
and/or
damage
to
property.
Overhead
rigging
requires
extensive
experience! Working load limits should be
respected, certified installation materials
should be used, the installed device
should be inspected regularly for safety.
BRITEQ
®
OPERATION MANUAL
3/64
BT-250W
ENGLISH
 Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.
 Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed at least 50cm from surrounding walls.
 The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.
 Before rigging make sure that the installation area can hold a minimum point load of 10times the device's
weight.
 Always use a certified safety cable that can hold 12times the weight of the device when installing the unit.
This secondary safety attachment should be installed in a way that no part of the installation can drop
more than 20cm if the main attachment fails.
 The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!
 Don't cover any ventilation openings as this may result in overheating.
 The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.
HOW TO SET UP THE UNIT
CONTROL PANEL:
1. DISPLAY shows the various menus and the selected functions.
2. LEDS
DMX
On
DMX input present
MASTER
On
Master mode
SLAVE
On
Slave mode
SOUND
Flashing
Sound activation
BRITEQ
®
OPERATION MANUAL
4/64
BT-250W