Notes:
l Protect the drain cover and water stopper properly.
l Move the unit carefully to avoid the leakage it is necessary.
l Tilt the unit slightly backwards when draining.
l Block the drain hole as soon as possible before the tray is full if it cannot hold all water
in the unit to prevent the water leakage and wet the floor or carpet.
l Water stopper and drain cover must be tightly installed, to avoid new condensate to
wet the floor or carpet when the unit re-starts working.
2. Continuous drainage
1) Screw off the drain-cover & unplug the water stopper.
2) Connect drain-hole with φ12mm drain hose, as deep as possible to avoid leakage.
3) Pull the drain hose to bathroom or outdoor.
Notes:
l Drain hose must be installed when there's no water in the tray.
l It is suggested that not to use continuous drainage when unit is in COOL mode, to
ensure enough water recycle in the unit to enhance the system cooling effects.
l It is suggested that to adopt continuous drainage when unit is in HEAT mode, to avoid
frequent drainage.
l Put the drain hose in an inaccessible place, not higher than drainage hole and keep
drain hose straight without any flexure.
l Keep the drain cover and its stopper properly when continuous drainage is adopted.
Multiple protection functions
1. Anti-frozen protection function
Under COOL mode, when the compressor continuously runs over 10 minutes, if tube
temperature is ≦2℃/36℉ for 20 seconds, the anti-frozen protection function will be
on, E4 will be shown on LCD display, compressor and water wheel motor will stop
working, but upper fan remains running; If tube temperature≧8℃/46℉, the unit will
stop anti-frozen protection and recover to the original working condition. Compressor
will re-start working with 3 minutes delay for protection.
2. Water-full safety alarm and shut –off protection function
When the water volume exceeds its alarm level in chassis, warning sounds
automatically and water-full icon
Drain Cover
is lighting in LCD display, you need to drain the
Drain hose

Publicité