4) Installation of the unit
A. Move the unit with the exhaust hose assembly installed in front of window and keep
the unit at least 50cm away from the walls or other objects.
B. Install the rectangle end of exhaust hose assembly into the corresponding rectangle
hole in window seal-plate assembly, fix it with screw and close the window.
Note:
l Slide the adapter downwards and assure adapter installed in good position.
l Assure the slant panel direction to match seal-plate direction.
l Exhaust hose cannot be bent or with flexure higher than 45°, in order to keep good
ventilation of exhaust hose.
Important notes:
The exhaust hose is 280mm-1500mm long and this length is determined based on the
specification of the air-conditioner (s). Do not use prolonged the hose or replace it with
other different hoses as this may affect the functions of the air-conditioner. The
exhaust hose must be smooth or it may lead air-conditioner overheat and damage.
Drainage Instruction
1. Manual drainage:
1) Once the unit shuts down upon water-full, turn off the unit and then unplug.
2) Put the tray below the water outlet at the back of the unit.
3) Screw off the drain cover, unplug the water stopper for water flow into the tray.
4) Plug in stopper and screw the drain cover tightly onto water outlet after drainage.