3.6.2
Indicators showing the battery's state of health
To check the battery's state of health, press the release button and hold it down for longer than three
seconds. The system does not detect a potential malfunction of the battery due to misuse, for example
battery dropped or pierced, external heat damage, etc.
Status
All LEDs show in sequence, followed by one (1)
LED showing constantly green.
All LEDs show in sequence, followed by one (1)
LED quick-flashing yellow.
All LEDs show in sequence, followed by one (1)
LED showing constantly red.
4
Technical data
4.1
Product
Weight without battery B22
Rated voltage
Belt speed
Belt dimensions
Belt tension
Arc of contact
Maximum pipe diameter
Ambient temperature for operation
Storage temperature
4.2
Battery
Battery operating voltage
Weight, battery
Ambient temperature for operation
Storage temperature
Battery charging starting temperature
*2332219*
Meaning
The battery can remain in use.
The check to ascertain the battery's state of health
did not complete. Repeat the procedure, or consult
Hilti Service.
If a connected product can still be used, the re-
maining battery capacity is below 50 %.
If a connected product can no longer be used, the
battery has reached the end of its useful life and
has to be replaced. Consult Hilti Service.
2332219
3 kg
(7 lb)
21.6 V
3.8 m/s ... 8.4 m/s
(12.5 ft/s ... 27.6 ft/s)
30 in x 1 1⁄2 in
4 kg ... 9 kg
(9 lb ... 20 lb)
270°
(4.7 rad)
125 mm
(4.9 in)
−17 ℃ ... 60 ℃
(1 ℉ ... 140 ℉)
−20 ℃ ... 70 ℃
(−4 ℉ ... 158 ℉)
21.6 V
See the end of these
operating instructions
−17 ℃ ... 60 ℃
(1 ℉ ... 140 ℉)
−20 ℃ ... 40 ℃
(−4 ℉ ... 104 ℉)
−10 ℃ ... 45 ℃
(14 ℉ ... 113 ℉)