Amana 12828148 Guide D'utilisation Et D'entretien page 15

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Water Filter
TM
Specifications
Service Flow Rate (Maximum).............................................0.78 GPM (2.9 L/min)
Rated Service Life UKF8001AXX-750 (Maximum) ......750 gallons /2838 liters
Maximum Operating Temperature .....................................100° F / 38° C
Minimum Pressure Requirement........................................35 psi / 241 kPA
Minimum Operating Temperature ......................................33° F/ 1° C
Maximum Operating Pressure.............................................120 psi /827 kPA
Performance Data
USEPA
Parameter
MCL
Chlorine
T & O
Particulate**
USEPA
Parameter
MCL
Turbidity
1 NTU**
Cysts
99.5% Reduction
Asbestos
99% Reduction
Lead at pH 6.5
0.015 mg/L
Lead at pH 8.5
0.015 mg/L
Mercury at pH 6.5
0.002 mg/L
Mercury at pH 8.5
0.002 mg/L
Atrazine
0.003 mg/L
0.005 mg/L
Benzene
Carbofuran
0.04 mg/L
0.075 mg/L
p-Dichlorobenzene
Lindane
0.0002 mg/L
Toxaphene
0.003 mg/L
* Tested using a flow rate of 0.78 gpm; pressure of 60 psig; pH of 7.5 + 0.5; temp. of
68° + 5° F (20° + 3° C)
** Measurement in Particles /ml. Particles used were 0.5 - 1 microns
*** NTU - Nephelometric Turbidity Units
General Use Conditions
Read this Performance Data Sheet and compare the
capabilities of this unit with your actual water
treatment needs.
DO NOT use this product where water is
microbiologically unsafe or of unknown quality
without adequate disinfection before or after the
system. System certified for cyst reduction may be
used on disinfected water that may contain
filterable cysts.
USE ONLY WITH COLD WATER SUPPLY. CHECK
FOR COMPLIANCE WITH THE STATE AND LOCAL
LAWS AND REGULATIONS.
(select models)
System Specification and Performance Data Sheet
Refrigerator Water Filter Cartridge Model UKF8001AXX
Standard No. 42: Aesthetic Effects
Influent
Challenge Concentration
2.0 mg /L ± 10%
at least 10,000 particles/ ml
Standard No. 53: Health Effects
Influent
Challenge Concentration
11 ± 1 NTU***
Minimum 50,000/L
10
7
10
8
fibers/L; fibers >10 micrometers in length
0.15 mg/L + 10%
0.15 mg/L + 10%
.006 mg/L ± 10%
.006 mg/L ± 10%
0.009 mg/L + 10%
0.015 mg/L ± 10%
0.08 mg/L ± 10%
.225 mg/L ± 10%
0.002 mg/L + 10%
0.015 ± 10%
Effluent
Influent
Average
Average
Maximum
1.88 mg /L
0.06 mg/L
< 0.05136364 mg/L
5,700,000 # /ml
30,583 # /ml
69,000 #/ml
Effluent
Influent
Average
Average
Maximum
10.7 NTU
0.31 NTU
.049 NTU
166,500 #/L
<1 #/L
<1 #/L
155 MF/L
<1 MF/L
<1 MF/L
0.153 mg/L
< .001 mg/L
< .001 mg/L
0.150 mg/L
<.001 mg/L
<.001 mg/L
0.006 mg/L
0.0003 mg/L
0.0005 mg/L
0.006 mg/L
0.0008 mg/L
0.0015 mg/L
0.009 mg/L
<0.002 mg/L
0.002 mg/L
0.014 mg/L
0.0006 mg/L
0.0011 mg/L
0.081 mg/L
<0.001 mg/L
<0.001 mg/L
0.208 mg/L
<0.0005 mg/L
<0.0005 mg/L
0.002 mg/L
0.000 mg/L
<0.0001 mg/L
0.015 mg/L
< 0.001 mg/L
< 0.001 mg/L
Tested and certified by NSF International against ANSI/NSF Standards 42 & 53
in models UKF8001AXX-750 for the reduction of:
Standard No. 42: Aesthetic Effects
Taste and Odor Reduction
Chlorine Taste & Odor
Mechanical Filtration Unit
Particulate Reduction Class 1
The PuriClean
II retractable water filtration system uses a
®
UKF8001AXX replacement cartridge. Timely replacement
of filter cartridge is essential for performance satisfaction
from this filtration system. Please refer to the applicable
section of your Use & Care Guide for general operation,
maintenance requirements and troubleshooting.
Suggested retail price of replacement water filter is $39.99.
This system has been tested according to ANSI/NSF 42 and
53 for reduction of the substances listed above. The
concentration of the indicated substances in water entering
the system was reduced to a concentration less than or
equal to the permissible limit for water leaving the system,
as specified in ANSI/NSF 42 and 53.
1000 Apollo Road
Eagan, Minnesota 55121-2240
651.450.4913
EPA EST #35917-MN-1
100834/B
% Reduction
Average
Minimum
>97.26%
96.84%
99.52%
98.94%
% Reduction
Average
Minimum
97.09%
95.20%
>99.99%
>99.99%
>99.99%
>99.99%
>99.35%
> 99.29%
>99.33%
>99.29%
95.70%
90.91%
86.22%
75.93%
76.99%
75.31%
95.71%
92.14%
98.74%
98.46%
99.76%
99.74%
98.72%
96.50%
92.97%
91.67%
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead, Atrazine, Lindane, Benzene,
Carbofuran, p-Dichlorobenzene, Mercury
& Toxaphene Reduction
Mechanical Filtration Unit
Cyst, Turbidity and Asbestos Reduction
Min. Required
Reduction
50%
85%
Min. Required
Reduction
0.5 NTU
> 99.95%
99%
0.10 mg/L
0.10 mg/L
0.002 mg/L
0.002 mg/L
0.003 mg/L
0.005 mg/L
0.04 mg/L
0.075 mg/L
0.0002 mg/L
0.003 mg/L
14

Publicité

Table des Matières
loading

Table des Matières