plate and the gate (see section 1. Wiring). Configure the switches at the back of the
intercom panel (see section 2. Configuring the intercom).
8 – Insert the screws and refit the two caps concealing the retaining screws.
Note:
screw through the black covers on the back of the intercom panel – do not remove
them.
9 – Refit the front cover of the intercom and tighten the tamper-resistant retaining screw.
10 - Connect the 230V AC power supply to the modular adaptor, for an installation compliant
with applicable standards (NFC 15-100 in France).
- Verify the smooth functioning (video call, etc.).
- When there is a second intercom panel, don't forget to configure the monitor(s).
11 - Attach a silicone seal* between the shield and the wall to stop flowing water. *Do not
use acetic acid-based silicone (vinegar odour).
5. Installing a camera (optional)
Connect the wires in accordance with the wiring diagram.
Choose a suitable place to install the camera.
Ensure that nothing gets in the way of the installation.
Screw the wall section with the screws provided (for solid walls).
Point the camera in the desired direction and tighten the retainer screw.
Configure the monitor(s)
6. Get more out of your device
To find out more about your Philips WelcomeEye product, you can download the complete
instructions at www.philips.com.
6. TECHNICAL CHARACTERISTICS
Monitor:
ref.: 531003 (WelcomeEye Comfort)
ref.: 531005 (WelcomeEye Compact)
- 2 wires
- 7" screen (Comfort), 4.3" screen (Compact)
- Resolution 800 x 480 (Comfort), 480 x 272 (Compact)
- Current consumption: 460mA (Comfort), 400mA (Compact)
- Power consumption: 11.1W (Comfort), 9.6W (Compact)
- 6 chimes (85dB)
- Dimensions: 142(h) x 210(l) x 15(d) (Comfort), 116(h) x 146(l) x 16(d) (Compact)
Intercom panel
ref.: 538200
- C-MOS colour sensor 900TVL
- Viewing angle H100° / V75°
- Night vision (white Leds)
- Strike plate control 12V/1.1A
- Gate control: breaking capacity 12V/2A
- IP44
- Operating temperature: -20°C / +50°C
On
WelcomeEye Comfort / Compact / 08/17
On
GB8