TROUBLESHOOTING
Hours of operation:
Monday to Thursday 8:30 am - 6:00 pm Eastern Standard Time
Friday 8:30 am - 4:00 pm Eastern Standard Time
Information in this manual is subject to change without notice.
PROBLEM
The appliance does not start
when pressing on/off button
The appliance changes from
COOL or HEAT to FAN mode
automatically
The indoor or outdoor
appliance are emitting white
mist
The indoor or outdoor
appliance are making noise
Dust is emitted from the
appliance
The appliance emits a bad
odor
The fan of the outdoor
appliance does not operate
Operation is erratic,
unpredictable, or appliance
is unresponsive
Poor cooling or heating
performance
The appliance starts and
stops frequently
Danby consumer care: 1-800-263-2629
• The appliance has a protection feature that prevents it from being turned back
on for 3 minutes after being turned off to avoid overloading
• Room temperature is lower than the set temperature. (Cooling mode)
• Room temperature is higher than the set temperature (Heat mode)
• Power failure
• A fuse is burned out
• Remote control batteries have burned out
• The appliance may change mode to prevent frost from forming on the internal
coils
• The set temperature has been reached, at which point the compressor is turned
off. The appliance will continue operating when the room temperature fl uctuates
from the set temperature
• In humid regions, a large temperature difference between the room temperature
and the set temperature can cause white mist
• When the appliance restarts in HEAT mode after defrosting, white mist may be
emitted due to moisture generated from the defrosting process
• A rushing air sound may occur when the louver resets its position
• A squeaking sound may occur after running the appliance in HEAT mode due to
the expansion and contraction of internal plastic parts
• A low hissing sound during operation is normal; this is caused by refrigerant gas
fl owing through the appliance
• The appliance may accumulate dust on the internal components during long
periods of non-use, which will be emitted when the appliance is turned on
• The appliance may absorb odors from the surrounding environment, (cooking
smells, animal smells, cigarette smells, etc.) which will be emitted during
operation
• The fi lter has become clogged and should be cleaned
• During operation, the fan speed on the outdoor appliance is controlled to
optimize product effi ciency
• Interference from cell phone towers and remote boosters may cause the
appliance to malfunction. To reset the appliance: disconnect the power then
reconnect and press the power button to restart operation
• Temperature setting is higher or lower than the ambient room temperature
• The outdoor temperature is extremely high or low
• The air fi lter is clogged
• The air inlet or outlet is blocked
• Doors and windows are open
• Low refrigerant due to leak or long-term use
• The heat exchanger is dirty
• There is too much or too little refrigerant in the system
• Incompressible gas or moisture has entered the system
• The voltage is too high or too low
• The compressor is malfunctioning
POSSIBLE CAUSE