Leakage Limits:
S
L
R
T
In order to calculate the leakage limits for your chosen model. Use the converter leakage current from the
table above and add the leakage current from modules, filter options and standby supply from the table
below.
Module/Filter/Standby
Option xxL
Option xxH
DH Module
DM Module
SB Module
SC Module
YB Module
YC Module
YF Module
ZC Module
ZD Module
ZF Module
Output Connections:
Module/Option
Global Option.
PMbus
DM module
J206 Option connector
DM module
DH module
J206 Option connector
DH module
SB module
J204 Option connector
SB module
SC module
J204 Option connector
SC module
SA module
SA module
J204 Option connector
Leakage Current
13.1µA
15µA
20.5µA
22.3µA
14.6µA
13.8µA
20.5µA
29.2µA
27.6µA
29.2µA
28.3µA
27.6µA
Connector
Housing
J1 Option connector
(Molex) 51110-
J5 Option connector
(Molex) 51110-
(Molex) 51110-
J202, J203, J204, J205
Power connectors
(Molex) 51110-
J202, J203, J204, J205
Power connectors
(Molex) 51110-
J202, J203
Power connectors
(Molex) 51110-
J202, J203
Power connectors
J202, J203
Power connectors
(Molex) 51110-
2.01mA (60950-1 & 62368-1 only)
214µA
77µA
60µA
Crimp pin
(Molex)
1060
50394-8051
(Molex)
1260
50394-8051
(Molex)
1260
50394-8051
-
-
(Molex)
1060
50394-8051
-
-
(Molex)
1060
50394-8051
-
-
(Molex)
1060
50394-8051
-
-
-
-
(Molex)
1060
50394-8051
Page 30 of 40
Output
Fast-on terminals
screw size
and torque
-
-
-
-
-
-
M3
Four 6.35mm
0.5 – 0.6Nm
ons. Each rated 18
Amps
-
-
M3
Four 6.35mm
0.5 – 0.6Nm
fast-ons. Each rated
18 Amps
-
-
M5
Four 9.5mm fast-ons.
2.4 -2.6Nm
Each rated 32 Amps
-
-
M5
Four 9.5mm fast-ons.
2.4 -2.6Nm
Each rated 32Amps
M5
Four 9.5mm fast-ons.
2.4 -2.6Nm
Each rated 32Amps
-
-