QM8 HANDBOOK
General Safety Instructions:
READ SAFETY INSTRUCTIONS
Servicing:
These products are not customer serviceable. TDK-Lambda UK LTD. and their authorised agents only are
permitted to carry out repairs.
Critical Components:
These products are not authorised for use as critical components in nuclear control systems, life support
systems or equipment for use in hazardous environments without the express written approval of the
Managing Director of TDK-Lambda EMEA.
Product Usage:
These products are designed for use within a host equipment which restricts access to authorised competent
personnel.
This product is a component power supply and is only to be installed by qualified persons within other
equipment and must not be operated as a stand-alone product.
This product is for sale to business to business customers and can be obtained via distribution channels.
It is not intended for sale to end users.
This product is a component power supply and does not fall within the scope of the EMC directive.
Compliance with the EMC directive must be considered in the final installation. Please contact your local
TDK-Lambda office
Environmental:
These products are IPX0, and therefore chemicals/solvents, cleaning agents and other liquids must not be
used.
Environment:
This power supply is a switch mode power supply for use in applications within a Pollution Degree 2,
overvoltage category II environment. Material Group IIIb PCB's are used within it.
Output Loading:
The output power taken from the power supply must not exceed the rating stated on the power supply label,
except as stated in the product limitations in this handbook.
Input Parameters:
This product must be operated within the input parameters stated in the product limitations in this handbook.
End of Life Disposal:
The unit contains components that require special disposal. Make sure that the unit is properly disposed of at
the end of its service life and in accordance with local regulations.
RISK OF ELECTRIC SHOCK
High Voltage Warning:
Dangerous voltages are present within the power supply. The professional installer must protect service
personnel from inadvertent contact with these dangerous voltages in the end equipment.
Page 1 of 40
260401-05 July 2019

Publicité

loading

Sommaire des Matières pour TDK-Lambda QM8

  • Page 1 General Safety Instructions: READ SAFETY INSTRUCTIONS Servicing: These products are not customer serviceable. TDK-Lambda UK LTD. and their authorised agents only are permitted to carry out repairs. Critical Components: These products are not authorised for use as critical components in nuclear control systems, life support systems or equipment for use in hazardous environments without the express written approval of the Managing Director of TDK-Lambda EMEA.
  • Page 2 An internal fuse protects the unit and must not be replaced by the user. In case of internal defect, the unit must be returned to TDK-Lambda UK LTD or one of their authorised agents. A suitable mechanical, electrical and fire enclosure must be provided by the end use equipment for mechanical, electric shock and fire hazard protection.
  • Page 3 Allgemeine Sicherheitsvorschriften: LESEN SIE DIE SICHERHEITSVORSCHRIFTEN Wartung: Diese Produkte können nicht durch den Kunden gewartet werden. Nur TDK-Lambda UK LTD. und deren zugelassene Vertriebshändler sind zur Durchführung von Reparaturen berechtigt. Kritische Komponenten: Diese Produkte sind nicht für die Verwendung als kritische Komponenten in nuklearen Kontrollsystemen, Lebenserhaltungssystemen oder Geräten in gefährlichen Umgebungen geeignet, sofern dies nicht...
  • Page 4 Produkt auf Erdschluss geprüft werden. Eine interne Sicherung schützt das Gerät und darf durch den Benutzer nicht ausgetauscht werden. Im Fall von internen Defekten muss das Gerät an TDK-Lambda UK LTD oder einen der autorisierten Vertriebshändler zurückgeschickt werden.
  • Page 5 Consignes générales de sécurité: LIRE LES CONSIGNES DE SECURITE Entretien: Ces produits ne peuvent pas être réparés par l’utilisateur. Seuls, TDK-Lambda UK LTD et ses agents agréés sont autorisés à effectuer des réparations. Composants critiques: Ces produits ne doivent pas être utilisés en tant que composants critiques dans des systèmes de commande nucléaire, dans des systèmes de sauvetage ou dans des équipements utilisés dans des environnements...
  • Page 6 Un fusible interne protège le module et ne doit pas être remplacé par l'utilisateur. En cas de défaut interne, le module doit être renvoyé à TDK-Lambda UK LTD ou l'un de ses agents agréés. Une enceinte appropriée doit être prévue par l'utilisateur final pour assurer la protection contre les chocs mécaniques, les chocs électriques et l'incendie.
  • Page 7 Questo alimentatore è da considerarsi come un componente e come tale non è assogettato dagli scopi della direttiva EMC. Conformità alla direttiva EMC deve essere considerata nell'installazione finale di utilizzo. Gli uffici di TDK-Lambda Sas Succursale Italiana sono a vostra disposizione per ulteriori ragguagli. Condizioni ambientali: Questi prodotti sono classificati come IPX0, dunque non devono essere utilizzati sostanze chimiche/solventi, prodotti per la pulizia o liquidi di altra natura.
  • Page 8 Un fusibile interno protegge l'unità e non deve essere sostituito dall'utente. Nell'eventualità di un difetto interno, restituire l'unità a TDK-Lambda UK LTD o a uno dei suoi agenti autorizzati. L'apparecchiatura finale deve includere una recinzione meccanica, elettrica e antincendio per proteggere dai pericoli di natura meccanica, dalle scosse elettriche e dai pericoli di incendio.
  • Page 9 Instrucciones generales de seguridad: LEA LAS INSTRUCCIONES DE SEGURIDAD Servicio: Estos productos no pueden ser reparados por los clientes. TDK-Lambda UK LTD. y sus agentes autorizados son los únicos que pueden llevar a cabo las reparaciones. Componentes fundamentales: Estos productos no pueden ser utilizados como componentes fundamentales en sistemas de control nuclear, sistemas de soporte vital o equipos a utilizar en entornos peligrosos sin el consentimiento expreso por escrito del Director General de TDK-Lambda EMEA.
  • Page 10 Un fusible interno protege la unidad y este no debe ser nunca reemplazado por el usuario. En caso de existir algún defecto interno, la unidad debe ser enviada a TDK-Lambda UK LTD o a uno de sus agentes autorizados.
  • Page 11 Instruções gerais de segurança: LEIA AS INSTRUÇÕES DE SEGURANÇA Manutenção: Estes produtos não são podem ser submetidos a manutenção por parte do cliente. Apenas a TDK-Lambda UK LTD e os seus agentes autorizados têm permissão para realizar reparações. Componentes essenciais: Não é...
  • Page 12 Existe um fusível interno que protege a unidade e que não deve ser substituído pelo utilizador. Em caso de defeito interno, a unidade deve ser devolvida à TDK-Lambda UK LTD ou a um dos seus agentes autorizados. O equipamento de utilização final deve fornecer um bastidor com protecção mecânica, eléctrica e contra incêndios adequada.
  • Page 13 QM8 HANDBOOK Special Instructions for medical applications IEC/EN 60601-1 3rd Edition ANSI/AAMI ES 60601-1 CSA C22.2 No 60601-1 These products are designed for continuous operation within an overall enclosure, and must be mounted such that access to the mains terminals is restricted.
  • Page 14 QM8 HANDBOOK Environmental Specifications: Description Operation Storage Indoor Temperature 0°C - +70°C (derating at 2.5%/°C above 50°C) -40°C - +70°C Humidity 5 - 95% RH, non-condensing 5 - 95% RH, non-condensing Altitude -200m - 5000m -200m - 5000m Pressure 54kPa - 106kPa...
  • Page 15 QM8 HANDBOOK Nomenclature: QM models as described below: Unit Configuration Code: QMshabcdefgklm for modular configurations Where: = 8 for QM8 models = Hold Up Option: Blank for none fitted H for Extended Hold Up B for 2000W version = Cooling: C for Customer air F for Variable speed, forward air fan.
  • Page 16 QM8 HANDBOOK Optionally followed by ‘Dxxx’ where xxx is the number of mV of droop. Droop option available by Non- Standard request only. Dual output modules v1/v2DHcde Where: = CH1 output voltage = CH2 output voltage = Module name: DH...
  • Page 17 QM8 HANDBOOK Series connected parallel modules vHxcde Where: = Output voltage = Series connected parallel SB or SC modules = Number of slots. (See Parallel and Series combinations Table below) = S for screw terminal output, F for faston = See letter from Module Signal Option Table = ‘C’...
  • Page 18 QM8 HANDBOOK Parallel and Series combination Tables Series connection, number of slots Qty of modules Name Slots Name Slots Name Slots Limitations of use: Output voltage is the combined modules voltage connected in series. Module limitations apply to modules connected in series.
  • Page 19 QM8 HANDBOOK DH outputs in series but split to create extra outputs Qty of modules Split after output x (first output is 1) Name Page 19 of 40 260401-05 July 2019...
  • Page 20 QM8 HANDBOOK Combined DM modules – seriesed Channel 1 only. Number of Nomenclature modules outputs v1/v2/v3MC v1/v2/v3/v4MD v1/v2/v3/v4/v5MF v1/v2/v3/v4/v5/v6MG v1/v2/v3/v4/v5/v6/v7MH v1/v2/v3/v4/v5/v6/v7/v8MJ v1/v2/v3/v4/v5/v6/v7/v8/v9MK Input Parameters: Input parameters Standard 60601-1 60950-1 100-240Vac 100-240Vac (166.7 - 240Vac)* (166.7 - 240Vac)* 200-240Vac** 200-240Vac** Nominal input voltage...
  • Page 21 QM8 HANDBOOK QM8 Output Parameters: Module output ratings table Number Output Vout Adjustment Output Output Hazardous Module Note of slots Channel nom (V) range Current (A) Power (W) Energy 5,8,11 11.9 to 16.1 16 to 21.6 20.8 to 28.2 2.8 to 3.8 4.25 to 5.75...
  • Page 22 QM8 HANDBOOK Output Output Number Vout Adjustment Output Hazardous Module Note Channe Power of slots nom (V) range Current (A) Energy 17 to 18.7 35.29 24 to 26.4 30 to 33 36 to 39.6 16.7 48 to 52.8 12.5 15 to 16 18 to 19.2...
  • Page 23 Fitted in slots 1 to 4 110A 100A Fitted in slots 3 to 8 110A 100A Fitted in slots 3 to 8 Cooling options QM8 Cooling option Input voltage (Vnom) Output power (W) Ambient °C 100-240* 1200 F (Forward air, variable speed) 166.7-240**...
  • Page 24 QM8 HANDBOOK 60950-1: Series modules For SB, SC and DM modules, all outputs are SELV except under the following circumstance: Outputs connected in series are non-SELV if, using the formula below, V is found to be >60Vdc Total = (n-1) × V...
  • Page 25 QM8 HANDBOOK If the total voltage of outputs connected in series exceeds the 60Vdc SELV limit then all outputs must be considered non-SELV. Non-SELV outputs are hazardous and must not be made user accessible. Consideration must be given to service engineers making inadvertent contact with the output terminals in the end equipment.
  • Page 26 QM8 HANDBOOK Module Slots Number Module ES1 (<42.4Vpk, ES2 (Anything above ES3 (anything above ES2) Code Description 60Vdc) ES1 but below (Module nominal voltage used) Outputs (Module nominal 70.7Vpk, 120Vdc) voltage used) (Module nominal voltage used) Modules connected in All YV modules are ES3...
  • Page 27 QM8 HANDBOOK Module Slots Number Module ES1 (<42.4Vpk, ES2 (Anything above ES3 (anything above ES2) Code Description 60Vdc) ES1 but below (Module nominal voltage used) Outputs (Module nominal 70.7Vpk, 120Vdc) voltage used) (Module nominal voltage used) Modules connected in 60/36, 60/45...
  • Page 28 QM8 HANDBOOK Module Slots Number Module ES1 (<42.4Vpk, ES2 (Anything above ES3 (anything above ES2) Code Description 60Vdc) ES1 but below (Module nominal voltage used) Outputs (Module nominal 70.7Vpk, 120Vdc) voltage used) (Module nominal voltage used) Modules connected in All LL modules are ES3...
  • Page 29 QM8 HANDBOOK Cooling for Unit Temperature Table: Circuit Ref. Description Max. Temperature (°C) Common Mode Choke 115 (140) Boost choke Electrolytic Capacitors 71 (105) Electrolytic Capacitors 64 (105) Electrolytic Capacitors 74 (105) Electrolytic Capacitors 73 (105) Electrolytic Capacitors 77 (105)
  • Page 30 QM8 HANDBOOK Leakage Limits: 2.01mA (60950-1 & 62368-1 only) 214µA 77µA 60µA In order to calculate the leakage limits for your chosen model. Use the converter leakage current from the table above and add the leakage current from modules, filter options and standby supply from the table below.
  • Page 31 QM8 HANDBOOK Mechanical Outline Drawings: Customer fixing points Maximum torque 1.1 to 1.3Nm Page 31 of 40 260401-05 July 2019...
  • Page 32 QM8 HANDBOOK Page 32 of 40 260401-05 July 2019...
  • Page 33 QM8 HANDBOOK Customer air Maximum torque 1.1 to 1.3Nm Page 33 of 40 260401-05 July 2019...
  • Page 34 QM8 HANDBOOK Option Pin Outs Page 34 of 40 260401-05 July 2019...
  • Page 35 QM8 HANDBOOK Secondary Option Pin Out Page 35 of 40 260401-05 July 2019...
  • Page 36 QM8 HANDBOOK Page 36 of 40 260401-05 July 2019...
  • Page 37 QM8 HANDBOOK Page 37 of 40 260401-05 July 2019...
  • Page 38 QM8 HANDBOOK Page 38 of 40 260401-05 July 2019...
  • Page 39 QM8 HANDBOOK Page 39 of 40 260401-05 July 2019...
  • Page 40 QM8 HANDBOOK Slot order TDK-Lambda UK Ltd Kingsley Avenue, Ilfracombe Devon, EX34 8ES Telephone - Sales and Service +44 (0)1271 856666 Head Office and Works +44 (0)1271 856600 Facsimile +44 (0)1271 864894 WEBSITE: www.uk.tdk-lambda.com Page 40 of 40 260401-05 July 2019...