ELECTRICAL INSTALLATION WITH CONNECTION CABLE
GROUNDING INSTRUCTIONS This appliance must be
grounded. In the event of an electrical short circuit, ground-
ing reduces the risk of electric shock by providing an escape
wire for the electric current. This appliance is equipped with
a cord having a grounding wire with a grounding plug. The
plug must be plugged into an outlet that is properly installed
and grounded.
WARNING - Improper grounding can result in a risk of electric
shock.
Consult a qualified electrician if the grounding instructions are
not completely understood, or if doubt exists as to whether
the appliance is properly grounded.
Do not use an extension cord. If the power supply cord is
too short, have a qualified electrician install an outlet near
the appliance.
ELECTRICAL INSTALLATION WITH
OPTIONAL WIRING BOX
For permanent wiring, use only the Direct Con-
nect Wiring Box accessory sku WIREBOX,
manufactured by Faber.
19
For Non-Ducted Recirculation
Attach a
charcoal
filter in the
correct
position and
block it by
the fixing
hooks as
shown.
Unlock the fixing hooks (towards the back of the
hood) to remove.
Required Activated Charcoal Filter
Accessory - sku # - FILTER2
(purchased separately)
12
Option
Direct Connect Wiring Box
Accessory sku # WIREBOX
(purchased separately)
Max. 33
"
7/16