RE-FUELLING WHEN BURNING WOOD
BURNING WOOD IN A SMOKE CONTROL AREA
To re-fuel your stove in the cleanest way only refuel your stove when flames have died down and you have
glowing embers. Before refuelling, open air controls fully and slide. Unlatch door to equalise pressure with the
room. Open door gently, add one piece of wood WESTFIRE UNIQ 15 & 16 and close the door. Once the flames from
the logs are fully established move air control to nominal position. The stove is only suitable for intermittent use
only: do not run overnight or for long periods unattended.
Experience will determine the settings that produce best results. Use a flue thermostat to check the stove is not
overheating. Flue thermostats should be placed directly above collar of the stove on a non insulated section of
pipe (efficient operating temperature range is between 200c and 400c?)
SE MODELS – smoke exemption modification
Smoke exempt models are factory fitted with a air stop on the air control slider:
SMOKELESS COAL, HOUSE COAL AND PETROLEUM COKE ARE NOT SUITABLE FOR USE ON THIS STOVE; ITS USE WILL
INVALIDATE THE GUARANTEE
SOLID SMOKELESS FUELS – Westfire UNIQ 15 & 16 models are NOT suitable for use with smokeless fuels and have
not been tested to the relevant European standard. Only use wood for these stoves.
Refuelling on to a low fire bed
If there is insufficient burning material in the firebed to light a new fuel charge, excessive smoke emission can
occur. Refuelling must be carried out onto a sufficient quantity of glowing embers and ash that the new fuel
charge will ignite in a reasonable period. If there are too few embers in the fire bed, add suitable kindling to
prevent excessive smoke.
Operation with door left open
Operation with the door open can cause excess smoke. The appliance must not be operated with the appliance
door left open except as directed in the instructions.
Dampers left open
Operation with the air controls or appliance dampers open can cause excess smoke. The appliance must not be
operated with air controls, appliance dampers or door left open except as directed in the instructions.
Fuel Overloading
The maximum amount of fuel specified in this manual should not be exceeded, overloading can cause excess
smoke.
Annual service
The inside of the stove should be serviced /cleaned once a year. To clean the inside, remove all ash, soot and
tar residue from the combustion chamber. Remove insulated chamber panels and baffle, dirt and soot will collect
behind it and this must be cleaned out. Insulated panels may crack if hit too hard by a piece of firewood. This has
no effect on the function of the stove (this is not the case with the smoke plate). The Insulated panels will only
need to be replaced once they become very worn and are no longer whole, or if they crack in several places,
replace stove door rope cord in the door. Check glass is correctly positioned.
The stove, the flue pipe connection and the chimney should be checked regularly by a qualified engineer. The
chimney should also be checked for blockages before relighting the stove if it has not been used for an extended
period of time.
WESTFIRE · WF15 WF16
Stove
WF15
WF16
Log length & weight
2 pieces approx 20 cm, 1.4 kg
2 pieces approx 20 cm, 1.4 kg
14