Complete the installation
ONLY FOR RECIRCULATING VERSION
(Using Recirculating Kit model KIT0141925)
Air deflector installation
Assemble the air deflector with the duct cover bracket
with 4 assembly screws provided as shown.
Measure from the bottom of the air deflector to the
bottom of the hood outlet, as shown:
Wall
outlet
Cut the duct at the measured size.
Uninstall the air deflector removing the 4 assembly screws.
Slip the duct onto the bottom of the deflector.
Place the assembled deflector and duct over the exhaust
outlet from the hood.
Place charcoal filters. See "Maintenance" section.
Electrical connection
I WARNING
ELECTRICAL SHOCK HAZARD.
I WARNING
DISCONNECT POWER BEFORE SERVICING.
REPLACE ALL PARTS AND PANELS BEFORE OPERATING.
FAILURE TO DO SO CAN RESULT IN DEATH OR
ELECTRICAL SHOCK.
1
Disconnect power.
2
Remove terminal box cover.
3
Remove the knockout in the terminal box cover and install
a UL listed or CSA approved
A
A.
Knockout
B.
Junction box cover
8
Dimension
to measure
⁄
" strain relief.
1
2
B
Run home power supply cable through strain relief, into
4
terminal box.
A
C
D
E
A.
Home power supply cable
B.
UL listed or CSA approved
strain relief
C.
Black wires
5
Use UL listed wire connectors and connect black wires
(C) together.
Use UL listed wire connectors and connect white wires (E)
6
together.
I WARNING
ELECTRICAL SHOCK HAZARD.
I WARNING
ELECTRICALLY GROUND BLOWER.
CONNECT GROUND WIRE TO GREEN AND YELLOW
GROUND WIRE IN TERMINAL BOX. FAILURE TO DO SO CAN
RESULT IN DEATH OR ELECTRICAL SHOCK.
Connect green (or bare) ground wire from home power
7
supply to yellow-green ground wire (F) in terminal box
using UL listed wire connectors.
8
Tighten strain relief screw.
9
Install terminal box cover.
10 Check that all light bulbs are secure in their sockets.
11 Reconnect power.
Mounting the duct cover
NOTE: Upper Duct Cover may be placed upside down to hide
(or unhide) louver holes.
Position the duct cover over the mounted hood.
Slide the bottom of the duct into the canopy area.
Position the top of the duct over the duct mounting bracket.
If a telescopic duct cover is used, grab the upper part of the
telescopic duct cover, pull it and place it in the duct cover
mounting bracket.
Secure the top of the duct with 2 assembly screws provided.
B
F
D.
UL listed wire connectors
E.
White wires
F.
Green (or bare) and
yellow-green ground wires