Problem
Splitting blade does not extend Hydraulic pump defective
Motor starts, but the splitting
blade does not extend
Motor does not start
In case of further faults or inquiries please contact your local dealer.
Technical data
Type / Model
year of construction
Splitting force
Hydraulic pressure
Feed speed 1
Feed speed 2
Return speed
Log length
Log diameter
Stroke
Hydraulic oil (max.)
Oil volume for oil change
Electric motor performance
Power supply
Sound pressure level L
PA
Dimensions (LxWxH)
Weight
Wiring diagram
Possible Cause
Motor turns in wrong direction
No power supply.
2-phase mode in threephase motor.
Mains cable defective.
Electric motor defective
ASP 16 N-2
160 kN (16 t)
27.7 Mpa (277 bar)
ca. 0.05 m/sek. (4.6 cm/sec)
ca. 0.14 m/sek. (14.2 cm/sec)
ca. 0.06 m/sek. (6.4 cm/sec)
80 – 300 mm
18.0 Litre
12.8 Litre
P
= 4500 W S6 40 %
1
257.8 kg
Remedy
To correct the problem, refer to the manufacturer
Check the motor direction
Threephase: adjust the motor direction
Check fuses.
Have fuse and lead checked by qualified electri-
cian.
Replace the connection cable or have it checked by
an electrician
To correct the problem, refer to the manufacturer
see last page
ca. 0,04 m/sek. (4,3 cm/sec)
ca. 0,10 m/sek. (10,5 cm/sec)
ca. 0,07 m/sek. (7,5 cm/sec)
560 - 1100 mm
Approx. 950 mm
P
400 V 3~ 50 Hz
≤ 80.0 dB (A)
1550 x 1050 x 2500 mm
Hydraulic diagram
Technical modifications reserved!
ASP 20 N-2
200 kN (20 t)
27.5 Mpa (275 bar)
80 – 350 mm
24.0 litre
17.5 Litre
= 5100 W S6 40 %
1
296.5 kg
21