Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal pres-
sures.
14855000: Only dishwashers and washing
machines certified with the DVGW emblem may be
connected to the appliance connection valve without
an additional fuse. If no consumer is connected to
the appliance connection valve, it must be plugged.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be oberserved.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
Fault
Insufficient water
Mixer stiff
Mixer dripping
Water escaping in area of swivel
spout
Water escaping at the threaded base - O-ring at the connection hose defec-
Hot water temperature too low
4
English
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80°C
65°C
max. 70°C / 4 min
Cause
- check valve hasn't moved back
- Cartridge defective, calcified
- Cartridge defective
- O-ring defective
tive.
- Hot water limiter incorrectly set
Assembly see page 31
Symbol description
Do not use silicone containing acetic acid!
Adjustment (see page 35)
To adjust the hot water limiter on single lever
mixers, please see page 35. Using a hot
water limiter in connection with a continuous
flow water heater is not recommended.
Dimensions (see page 36)
Flow diagram
(see page 36)
Spare parts (see page 38)
Operation (see page 37)
Hansgrohe recommends not to use as drink-
ing water the first half liter of water drawn
in the morning or after a prolonged period
of non-use.
Cleaning
see enclosed brochure.
Test certificate (see page 40)
Remedy
- Exchange check valves
- Exchange cartridge
- Exchange cartridge
- Exchange O-ring
- Exchange O-ring
- Set hot water limiter