Télécharger Imprimer la page

Novy 7931.400 Mode D'emploi page 10

Le caisson recyclage avec filtre monobloc

Publicité

Les langues disponibles

Les langues disponibles

GENERAL INFORMATION
These are the mounting instructions for the product shown on the cover. Carefully read these instructions before installation
and commissioning. It is recommended to have one or more qualified persons carry out the installation only.
Carefully remove the content from the packaging and check the materials. Do not use sharp knives to open the packaging.
In case of damage, immediately contact your dealer.
INSTALLATION
Follow the mounting drawings on page 2.
Positioning the discharge opening:
1
Before installation, you must determine where the outlet opening should be; top / bottom or back / side, this
depending on the installation location (ceiling, wall or plinth).
a. For outlet top or bottom, close the rectangular exit on the side or back:
2
- Unscrew the discharge opening
- Stick the mousse board on the edges of the cover plate (supplied)
- Place the cover plate in front of the outlet opening
- Mount the the discharge opening with the screws.
b. Remove the pre-perforated passage and the underlying isolation.
c. If you want to place the discharge opening at the back:
- Unscrew the discharge opening
- Turn the discharge opening
- Screw the discharge opening back with the opening at the back.
Provide an opening in the plinth / wall or ceiling with the following dimensions:
3
123x805 mm (tolerance -0 / + 1 mm)
Provide sufficient installation space: the minimum installation depth = 295mm
Minimum height of the plinth: 150mm
Depending on the location, be aware of the cutting out openings in the plinth or ceiling.
Make an opening in the kitchen cabinet to have access to the connection. Mark the positioning from the opening for
4
the round connection pipe / outlet and make a suitable opening here. Keep in mind the type of tube (round ø150 mm
or flat 89x222x1000 mm).
Open the built-in box by pressing on the side (sticker "press here") until you hear a click. The grid is now completely
5
loose. Remove the monoblock filters from the recirculation box.
Place the recirculation box in the created opening.
6
Adjust the height of the box with the adjusting screw on the inside of the recirculation box or use another one support
7
to place the box straight in the opening for optimal results.
Screw the recirculation box by hand (not too tight!) With the supplied screws.
8
Only when using the discharge opening at the top or bottom:
9
Stick the mousse board to the bottom of the round connector (supplied) and screw it onto the
installed recirculation box.
Put the monoblock filters back in the opening and close the grid.
10
The duct must be connected to the openings on the recirculation box. Mount carefully with aluminum tape (supplied
906.292).