38 | SBM V655 | Wheel balancing
8.2
Entering rim data
i
If electronic recording is not possible, the wheel
data can also be entered manually (main page <F1>
or in program selection <F5>).
i
The electronic gauge arm is not required for
the balancing programs Alu2, Alu3 and Pax2
(ALUDATA®). Both measurement locations are
recorded with the vernier caliper.
1. Apply the electronic vernier caliper for rim distance
and rim diameter to the rim.
651012-12_Sr
« The measurement location is indicated on the
monitor in accordance with the balancing program
selected.
« Storage of the position is confi rmed by an acoustic
signal and the position data are displayed.
i
The electronic vernier caliper can be used to record
rim diameters of up to 26". The data of wheels with a
rim diameter between 26" and 30" must be recorded
manually (main page <F1> or in program selection
<F5>).
|
656 234
2010-11-22
2. Apply the electronic gauge arm for rim width to the rim.
651012-32_Sr
« The measurement location is indicated on the
monitor in accordance with the balancing program
selected.
« Storage of the position is confi rmed by an acoustic
signal and the position data are displayed.
"
The individual values have now been read in and are
displayed on the monitor.
i
Refer to Section 10. if the values are not read in
automatically.
8.3
Measuring unbalance
i
A wheel can only be correctly balanced if all the
settings correspond to the clamped wheel.
i
Measurement can be stopped at any time:
$
Press <F1> (STOP).
$
Press the pedal downwards.
$
Open the wheel guard.
1. Close the wheel guard.
« The unbalance measurement commences
automatically.
« On completion of the measurement the masses
and positions of the balance weights are indicated
on the monitor.
« The wheel is automatically braked after the
measurement and stopped and fi xed in the correct
position for attachment of a balance weight.
2. Open the wheel guard.