Samara RTB
English
basis of that specified by Article 3 paragraph 3 of the Directive.
In the case that the original copy of the Declaration of Product Conformity
provided with the product is lost, it is possible to download a copy by completing
the form found at the following website: http://www.arneg.it/conformity
The performance of these refrigeration units has been determined using tests carried
out in accordance with UNI EN ISO 23953-2: 2006 regulations, in the environmental
conditions corresponding to climate class 3 (25 °C , 60% R.H.)
Environmental climatic classes according to UNI EN ISO 23953 - 2
Climatic class
1
2
3
4
5
6
6. Identification - Plate data (Rif. 2)
A serial plate is affixed behind the unit, stating all characteristic data:
1) Manufacturer's name and address
2) Unit name and length
3) Unit code
4) Unit serial number
5) Voltage supply
6) Supply frequency
7) Current used when operating
8) Electrical power used when operating during refrigeration phase (fans+hot
cables+lighting)
9) Electrical power used when operating during defrost phase (armoured
resistances+hot cables+fans+lighting)
10) Lighting power (where applicable)
11) Net display surface
12) Type of refrigerant fluid with which the system functions
13) Mass of refrigerant gas with which each system has been loaded (only for units
with built-in motor)
14) Environmental climatic class and temperature of reference
15) Humidity protection class
16) Unit manufacturing order number
17) Unit production order number
18) Unit year of production
In the case of a request for technical assistance, please provide the following
information:
product name (Rif. 2 - 2); serial number (Rif. 2 - 4); work order number (Rif. 2 - 16).
7. Transport - specialised technician -
Loading/unloading operations must always be carried out by qualified personnel able
to check weights, exact lifting points, and the most appropriate means of transport,
both in terms of safety and capacity. The cabinets are supplied on a wooden platform
frame to the base for movement with forklift trucks. Use a manual or electrical forklift
truck that is suitable for moving the cabinet in question. It must have a nominal
capacity of at least 1,000 kg.
Always place the forks at the indicated points in order to avoid the risk of
overturning, and always completely insert the forks.
No unnecessary personnel should be present in the lifting area.
Balance the weight of the unit so as to ensure that the load remains in
equilibrium (Rif. 3)
22
Temp. dry bulb
Relative humidity
16°C
22°C
25°C
30°C
40°C
27°C
Dew point
80%
65%
60%
55%
40%
70%
12°C
15°C
17°C
20°C
24°C
21°C