Medisana TargetScale 3 Mode D'emploi page 9

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
Troubleshooting
O-LD = The scale is overloaded; LO = The battery is low and must be replaced.
ERR/ERR2 = Body analysis could not be completed.
"-----" = get off the scales first and wait until the device has turned off. Restart a measurement afterwards.
"□□□□□" = bodyfat analysis in progress. Do not get off the scales during this measurement process! The
measurement is finished, when the display shows the correct weight.
If your personal scales do not function to your satisfaction, check the following before contacting a
service centre:
Check whether the batteries have been inserted correctly.
Check whether the correct unit of weight has been selected.
Check whether the scales are freestanding on a solid and even surface. They must not be touching
a wall or any other object.
Weigh yourself again.
Insert/replace batteries
Replace the batterie if the battery change symbol "LO" appears in the display or if nothing appears in
the display after you have stepped on the device. Insert the four 1.5 V batteries (type AA) into the
device. To do this, open the battery compartment beneath the device and insert the batteries.
Make sure the polarity is correct.
Disposal
This product must not be disposed of together with domestic waste. All users are obliged to
hand in all electrical or electronic devices, regardless of whether or not they contain toxic
substances, at a municipal or commercial collection point so that they can be disposed of in
an environmentally acceptable manner. Please remove the batteries before disposing
of the device/unit. Do not dispose of old batteries with your household waste,
but at a battery collection station at a recycling site or in a shop.
Warranty and repair terms
Please contact your dealer or the service centre in case of a claim under the warranty. If you have to return
the unit, please enclose a copy of your receipt and state what the defect is.
The following warranty terms apply:
1. The warranty period for MEDISANA products is three years from date of purchase. In case of a warranty
claim, the date of purchase has to be proven by means of the sales receipt or invoice.
2. Defects in material or workmanship will be corrected free of charge within the warranty period.
3. Repairs under warranty do not extend the warranty period either for the unit or for the replacement
parts.
4. The following is excluded under the warranty:
a. All damage which has arisen due to improper treatment, e.g. nonobservance of the user instructions.
b. All damage which is due to repairs or tampering by the customer or unauthorised third parties.
c. Damage which has arisen during transport from the manufacturer to the consumer or during
transport to the service centre.
d. Accessories which are subject to normal wear and tear (batteries etc.).
5. Liability for direct or indirect consequential losses caused by the unit are excluded even if the damage
to the unit is accepted as a warranty claim.
Medisana GmbH
Jagenbergstraße 19, 41468 NEUSS
GERMANY
E-Mail: info@medisana.de
Internet: www.medisana.com
TargetScale 3
Instruction Manual GB
9

Publicité

Table des Matières
loading

Table des Matières