REPLACING THE LIGHT BULB
1. Disconnect the fridge.
2. Remove the drip tray.
3. The bulb is behind the thermostat panel.
4. Remove the bulb by unscrewing it counter
clockwise.
5. Screw in a new 10W bulb.
A fridge makes a certain number of noises that are perfectly normal:
The coolant gas can create a gurgling sound as it circulates through the system.
The compressor can rumble, a sound which can be more intense when it starts up.
Sharp cracking sounds produced by expansion and contraction of the materials used.
PROBLEM
The fridge does not operate
The fridge vibrates or makes noise
The fridge is too cold/not cold
enough
The fridge light does not come
one
The compressor does not restart
after a temperature change
There is water on the floor or the
racks
TECHNICAL ASSISTANCE SERVICE
If you have carried out the above checks, and your problem persists, ATTEMPT NO REPAIRS
YOURSELF. Contact the nearest Technical Assistance Service.
THIS APPLIANCE IS IN CONFORMITY WITH EC DIRECTIVES

OPERATING PROBLEMS

Check that it is properly plugged in, that the fuse has not blown
or that the circuit-breaker has not tripped.
Check that it is perfectly level. Adjust the feet.
Check the thermostat and set it to a more appropriate
temperature.
Check the bulb and change it if necessary. Also check that the
plug is correctly inserted, that the fuse has not blown or that the
circuit-breaker has not tripped.
This is normal, as the compressor only restarts after a certain
time.
The drain hole is blocked. Unclog it with a knitting needle.
2006/95, 2004/108, 96/57, 92/31, 94/62
6. Fit the drip tray, reconnect the appliance