Vending
Models Starting Serial No 0909
Cool Down Per Cycle
(in minutes)
3 (preset at factory)
6
Total Cycle Time = Heat Time + Cool Down Time
Test Setting
When testing coin slide operation or other
troubleshooting, set dipswitch with this shorter cycle:
1. Unplug the machine power cord.
2. Record the machine control dipswitch settings.
Then set them all to the off position. Refer to
Figure 29.
30
Table 6 (continued)
Cool Down
Switch Number
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
7
OFF
ON
Table 6
3. Plug in the machine and initiate a cycle.
NOTE: With all the control dipswitches off, the
total cycle time will be four minutes long.
4. Once all the testing is complete, unplug the
machine and re-set the dipswitches to their
original settings.
5. Plug in the machine.
1 2 3 4 5 6 7 8
O
N
Figure 29
Cycle Reset
Switch Number
8
OFF
ON
DRY2225P
DRY2225P
512681