ALLIANCE D677I Installation/Fonctionnement/Entretien page 23

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Three-Wire Plug
NOTE: The power cord (pigtail) is NOT supplied with the electric
dryer. Type of pigtail and gauge of wire must conform to local
codes and instructions.
The method of wiring the dryer is optional and subject to local
code requirements.
NOTE: Connect the dryer to the power supply with the
MAXIMUM RATED VOLTAGE listed on the nameplate.
120 ± 12
V.A.C.
240 ± 12
V.A.C.
NOTE: Use COPPER WIRE only.
Shorter than 4.5 m (15') use 10 A.W.G.
Longer than 4.5 m (15') use 8 A.W.G.
1
3-Wire Grounded Neutral 120/240 Volt, 60 Hertz
AC 1 Phase Service Entrance Switch Box
(Refer to NOTE above)
2
30 Ampere Fuses or Circuit Breaker
3
Neutral Wire
To Convert from 4-Wire Connection to 3-Wire
Connection
1. Disconnect power to dryer.
2. Remove access cover from rear of dryer.
Figure 22
512681
A typical
INTERMEDIATE
30-Amp
FUSE BOX (May
Three-wire
be omitted if
Receptacle
service entrance
NEMA Type
box is fused)
10-30R
WALL RECEPTACLE
120 ± 12
V.A.C.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
POWER SUPPLY
L1
L2
PIGTAIL CONNECTION
4
Metallic or Non-Metallic Sheathed Cable
(Copper wire only)
5
Pigtail to Dryer (Refer to NOTE above)
6
Neutral Wire
7
Terminal Block in Dryer
Figure 21
D695I
Installation
POWER SUPPLY
1
2
3
INTERMEDIATE
SHUT-OFF BOX
(May or may
not be fused)
4
5
6
7
L1
L2
DIRECT CONNECTION
D816I
21