INSTALLATION INSTRUCTIONS
Insulation
Wooden parts of any coverings or structures must be protected by fireproof panels. No points of contact should be present with
the fireplace and they must be positioned outside the area of radiation.
These same parts in wood must also be spaced at least 1 cm from the fireplace structure to allow an air flow which hinders heat
accumulation.
Surrounding chimney structure
The surrounding chimney structure can be made from fireproof drywall panelling or sheets of plaster; the hot air circulation
grilles must be installed while the structure is being assembled:
- mount the covering up to the beam, and then set the mantel in place.
Electrical connections
- the electrical connections must be properly installed and conform to the installation standards
- do not allow the electrical wiring to come into contact with the SCREEN body, the smoke tubing or any other hot components
- the electric and electronic equipment supplied with the fireplace may not be tampered with in any manner
- the electric and electronic components are always live; always remove the plug from the outlet, or shut off the circuit breakers
to the home, before any interventions.
aluminium pipe ø 14 cm for
warm air to be channelled
warm air inlet grille
(into the mantel)
chimney flue
aluminium pipe ø 14 cm for
warm air to be channelled
- 28
-
warm air outlet grille
(from the mantel)
mantel