To change the by-pass screw, unscrew completely the screw located on the left of
the tap and replace it by corresponding screw.
For a use in natural gas, change the injectors (burner + pilot light (Ø 45). They are
delivered in a small plastic bag in the package. Unscrew completely the nut and then
the injector located on the hole. The low flame of the appliance is regulated by un-
screwing the by-pass screw to obtain a flow of 4KW.
Gas modification for SGM 800 and SGF 800
Gas category table, according to the country of destination of the appliance.
Country of des-
Category
tination
France/
II2E+3+
Luxembourg
II2E+3B/P
Germany
II2E3B/P
Austria
II2H3B/P
Sweden/Danemark
II2H3B/P
Finland
Spain
II2H3+
II2H3P
Netherlands
II2L3B/P
II2L3P
Norway
I3B/P
Islande/Greece/
II2H3+
Great Britain /Italy
Portugal
II2H3+
N°injector
Injector n°1
G30/G31
Injector n°2
G30/G31
Injector n°3
G20/G25
Injector n°4
G25
Gas
Pres-
sures
G20/25
20/25
G30/G31
28-30/37
G20/G25
20/25
G30/G31
50
G20/G25
20
G30/G31
50
G20
20
G30/G31
50
G20
20
G30/G31
28-30/30
G20
20
G30/G31
28-30/37
G20
20
G31
50
G25
25
G30/G31
28-30/37
G25
25
G31
50
G30/G31
28-30/30
G20
20
G30/G31
28-30/37
Gas
Butane/Propane
Butane/Propane
Gaz naturel
Gaz naturel
Injector
By-Pass
diameter
screw
diameter
150
Adjustable
100
110
150
Adjustable
90
95
150/160
Adjustable
90
95
150
Adjustable
90
95
150
Adjustable
100
110
150
Adjustable
100
110
150
Adjustable
90
95
150
Adjustable
100
110
150
Adjustable
90
95
100
110
150
Adjustable
100
110
Pressure
Diameter
28-30/37
100/100
50
90/100
20-25
150100
20
160/100
Air
setting
ring
Without
Without
Without
Without
Without
Without
Without
Without
Without
Without
Without
Without
Without
Without
Without
Without
Without
Without
Without
Without
Without
18