- Never place the device near a wall or near a partition makes of combustible materi-
als even if it is very well isolated.
- A distance of minimum 40 cm with the partition, the wall or any other appliance is
necessary.
- Remove the protective film from the top, the rear, the sides and the tray.
- Unlock the movable top by unscrewing the screw located on the back of the ma-
chine thanks to a 10 pipe key (models SGM 600 and SGM 800).
CAUTION :
During use: never place the machine on surfaces or near walls, partitions or
kitchen furniture and similar— except if they are made with a non combustible
material or recovered with non combustible thermic insulation, and pay atten-
tion to fire preventions rules.
b) First starting:
During the first use, warm your machine up outside during about 30 min to evacuate
residual smokes of manufacturing oil from the metallic parts. This may emit a slight
smell for a few moments.
First cleaning
Clean the device before the first use. (See 6 Cleaning)
Gas connection
The appliances run on the following gases: Butane G30, Propane G31, Natural gas
G20/G25. The appliances are originally delivered with a Butane/Propane injector
(85/100 for SGM 600, 100/100 for SGM 800 and SGF 800) corresponding to the cat-
egory II2E+3+, under pressure of 28/30/37mbar. The connection is made thanks to a
thread G 1/2.
The heat release rate of the appliance is
- SGM 600
5,0 kW
- SGM 800
7.6 kW
- SGF 800
7,6 kW
Check the supply pressure using a manometer when all the burners are lit. It must be
equal to the indications on the rating plate.
The fresh air flow required for combustion air supply is:
- SGM 600
10m3/h
- SGM 800
15m3/H
- SGF 800
15 m3/H
15