VOLTCRAFT AT-200 Notice D'emploi page 40

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Overload protection: µA/mA 0.5A 250V quick-acting fuse
Duration of measurement in the 10A range:
AC ampere
Overload protection: µA/mA 0.5A 250V quick-acting fuse
Duration of measurement in the 10A range:
Frequency of the alternating voltage: 50 Hz to 400 Hz
Resistance
Overload protection: 250 V
Continuity tester: acoustic signal for resistances <150 Ω, test current: <0.3mA
Diode test
Capacity
Overload protection: 250 V
Frequency
Overload protection: 250 V
Measuring sensitivity up to 1MHz: 500 mV
40
400 mA
4 A
10 A
10 A
250 V
400 µA
4000 µA
40 mA
400 mA
4 A
10 A
10 A
10A 250 V
400 Ω
4 kΩ
40 kΩ
400 kΩ
4 MΩ
40 MΩ
Test voltage, max. 1.5 V (max. 0.3mA)
40 nF
400 nF
4 µF
40 µF
100 µF
5 Hz
50 Hz
500 Hz
5 kHz
50 kHz
500 kHz
10 MHz
> 1 MHz 3V
+/-(1.8%+3dgt)
+/-(2.5%+5dgt)
+/-(2.5%+5dgt)
quick-acting fuse
0 up to </=5 A permanent measurement
> 5A max. 30 sec with a pause of 15 min
+/-(1.5%+3dgt)
+/-(1.8%+5dgt)
+/-(1.8%+5dgt)
+/-(2.0%+5dgt)
+/-(3.0%+7dgt)
+/-(3.0%+7dgt)
quick-acting fuse
0 up to </=5 A permanent measurement
> 5A max. 30 sec with a pause of 15 min
+/-(1.5%+5dgt)
+/-(1.3%+3dgt)
+/-(1.5%+3dgt)
+/-(1.5%+3dgt)
+/-(1.5%+3dgt)
+/-(2.5%+4dgt)
+/-(6%+12dgt)
+/-(3.5%+7dgt)
+/-(3.5%+7dgt)
+/-(3.5%+7dgt)
+/-(6%+7dgt)
+/-(1.8+6dgt)
+/-(1.8+6dgt)
+/-(1.5+4dgt)
+/-(1.5+4dgt)
+/-(1.5+4dgt)
+/-(1.5+4dgt)
+/-(2.0+5dgt)
0.1mA
0.001 A
0.01 A
0.1 µA
1 µA
0.01 mA
0.1mA
0.001 A
0.01 A
0.1 kΩ
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.01 nF
0.1 nF
0.001 µF
0.01 µF
0.1 µF
0.001 Hz
0.01 Hz
0.1 Hz
1 Hz
10 Hz
100 Hz
1 kHz

Publicité

Table des Matières
loading