Specifications
Relay outputs:
Programmable relay outputs
Relay 01 Terminal number
Max. terminal load (AC-1)
Max. terminal load (AC-15)
Max. terminal load (DC-1)
Max. terminal load (DC-13)
Relay 02 Terminal number
Max. terminal load (AC-1)
Max. terminal load (AC-15)
Max. terminal load (DC-1)
Max. terminal load (DC-13)
Max. terminal load (AC-1)
Max. terminal load (AC-15)
Max. terminal load (DC-1)
Max. terminal load (DC-13)
Min. terminal load on 1-3 (NC), 1-2 (NO), 4-6 (NC), 4-5 (NO)
Environment according to EN 60664-1
1)
IEC 60947 part 4 and 5
The relay contacts are galvanically isolated from the rest of the circuit by reinforced isolation (PELV).
8
8
2)
Overvoltage Category II
3)
UL applications 300V AC2A
Cable lengths and cross-sections for control cables:
Max. motor cable length, shielded
Max. motor cable length, non-shielded
Maximum cross-section to control terminals, flexible/ rigid wire without cable end sleeves
Maximum cross-section to control terminals, flexible wire with cable end sleeves
Maximum cross-section to control terminals, flexible wire with cable end sleeves with collar
Minimum cross-section to control terminals
Control card performance:
Scan interval
Control characteristics:
Resolution of output frequency at 0–1000Hz
Repeat accuracy of Precise start/stop (terminals 18, 19)
System response time (terminals 18, 19, 27, 29, 32, 33)
Speed control range (open-loop)
Speed control range (closed-loop)
Speed accuracy (open-loop)
Speed accuracy (closed-loop), depending on resolution of feedback device
Torque control accuracy (speed feedback)
All control characteristics are based on a 4-pole asynchronous motor
36
AF-650 GP Quick Guide
1)
on 1-3 (NC), 1-2 (NO) (Resistive load)
1)
(Inductive load @ cosφ 0.4)
1)
on 1-2 (NO), 1-3 (NC) (Resistive load)
1)
(Inductive load)
1)
on 4-5 (NO) (Resistive load)
1)
on 4-5 (NO) (Inductive load @ cosφ 0.4)
1)
on 4-5 (NO) (Resistive load)
1)
on 4-5 (NO) (Inductive load)
1)
on 4-6 (NC) (Resistive load)
1)
on 4-6 (NC) (Inductive load @ cosφ 0.4)
1)
on 4-6 (NC) (Resistive load)
1)
on 4-6 (NC) (Inductive load)
2)3)
Overvoltage cat. II
overvoltage category III/pollution degree 2
DET-759A
2 Form C
1-3 (break), 1-2 (make)
240V AC, 2A
240V AC, 0.2A
60V DC, 1A
24 V DC, 0.1A
4-6 (break), 4-5 (make)
400V AC, 2A
240V AC, 0.2A
80V DC, 2A
24 V DC, 0.1A
240V AC, 2A
240V AC, 0.2A
50V DC, 2A
24 V DC, 0.1A
24V DC 10mA, 24V AC 20mA
492 ft [150 m]
984 ft [300 m]
2
1.5mm
/16 AWG
2
1mm
/18 AWG
2
0.5mm
/20 AWG
2
0.25mm
/ 24AWG
1 ms
± 0.003Hz
≤± 0.1ms
≤ 2ms
1:100 of synchronous speed
1:1000 of synchronous speed
30–4000 rpm: error ±8rpm
0–6000 rpm: error ±0.15 rpm
max error±5% of rated torque