Télécharger Imprimer la page

ARIETE Moka aroma 1337 Mode D'emploi page 17

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
PROBLEMS
CAUSES
Coffee overflowing
Probably an excess amount of
from the edges of the
ground coffee has been placed
filter ring.
in the filter ring preventing the
filter ring from being correctly
tightened into its housing.
Residues of ground coffee have
remained on the gasket of the
filter holder coupling seat.
The hole of the silicone disc is
clogged.
The exit holes of the filter
containing coffee grounds are
clogged.
Faulty pod.
the coffee is not
The holes of the perforated disc
supplied or flows too
in the filter holder coupling seat
slowly.
are clogged.
The exit holes of the filter
containing coffee grounds are
clogged.
The coffee blend is ground too
fine.
The coffee blend is pressed
down too much.
The tanks is not inserted well.
The hole of the silicone disc is
clogged.
There is little water and the pump
does not suck it up.
Faulty pod.
Broken pod.
the coffee is too
The blend has been ground too
watery and cold.
coarsely.
SOLUTIONS
Slowly remove and disconnect the filter holder because
any remaining pressure could cause splashes or squirts.
Clean the coupling seat with a sponge (Fig. 12). Repeat
the operation placing the correct quantity of coffee in the
filter.
Clean the seal with a toothpick or a sponge (Fig. 12).
Wash the silicone disc (I) under running water, bending it
slightly on the sides in order to free the centre hole of any
residue of coffee grounds that could clog it (Fig. 11).
Slowly remove and disconnect the filter holder because
any remaining pressure could cause splashes or squirts.
Clean the clogged filter holes with a small brush or a pin.
Clean the filter using Ariete COFFEE CLEAN tabs, follow-
ing the instructions provided in the package.
Replace the pod in the filter holder (U).
Turn on the machine without the filter holder, making the
water run. Turn on the machine without the filter holder,
making the water run. If the water still does not come out
from all the holes evenly, carry out the descaling cleaning
operation using the Ariete NOCAL product found at Ariete
service centres, following the instructions provided in the
package.
Slowly remove and disconnect the filter holder because
any remaining pressure could cause splashes or squirts.
Clean the clogged filter holes with a small brush or a pin.
Clean the filter using Ariete COFFEE CLEAN tabs, follow-
ing the instructions provided in the package.
Try using coarser coffee blends.
amper coffee inside the filter using less pressure.
Fit the tank securely by pushing it as far as it will go.
Wash the silicone disc (I) under running water, bending it
slightly on the sides in order to free the centre hole of any
residue of coffee grounds that could clog it (Fig. 11).
Check that the water level in the tank is correct. If neces-
sary, fill it with cool tap water.
Replace the pod in the filter holder (U).
Remove the pod filter holder (U), clean the seat with a
sponge, and put a new pod inside.
A more finely ground blend must be used to obtain a more
concentrated and hotter coffee. Anyhow, this problem is
easily solved thanks to the Thermocream® System, which
always guarantees hot coffee accompanied by a reach
cream, even with coarsely ground beans.
17

Publicité

loading