Thermal disinfection
This is only possible for the eSET Touchfree with temperature
setting.
If regular thermal disinfection is called for, the system can be
activated so that hot water runs from the fitting for 5 minutes.
Thermal disinfection requires hot water of at least 70 °C / 158 °F
to be available and the thermostat must be set to hot.
!
WARNING!
Danger of Scalding Due to Hot Liquids!
– During thermal disinfection, the water that emerges can reach
a temperature of 70 °C / 158 °F or more.
– Avoid any contact with the water jet and the water spray!
– Any scalds should be examined by a physician and treated, if
necessary.
!
WARNING!
Danger of Burning Due to Hot Surfaces!
– The very hot water flowing through the spout can heat it up.
– Avoid touching the spout during thermal disinfection and for
5 minutes afterwards.
– Any burns should be examined by a physician and treated, if
necessary.
!
WARNING!
Danger of Scalding Due to Hot Liquids!
– The thermostat must be reset to the normal temperature
immediately after thermal disinfection!
Maintenance
Once a month, operate the thermostat at full flow over the
entire temperature range, to ensure perfect operation. Dornbracht
recommends to maintain the product professionally once a year.
Technical information
Rated voltage
Input frequency
Output voltage
Rated power
Degree of protection
Permissible Ambient Temperature
Sensor frequency
14
English
– Any scalds should be examined by a physician and treated, if
– Please refer to the water temperature settings on page 13 for
CLEANING STOP
Keep your finger on the "CLEANING STOP" dot of the Touchfree
box for longer than 10 seconds. You hear a beep. The system is
then in thermal disinfection mode. Hot water flows continuously.
If you keep your finger on the "CLEANING STOP" dot of the
Touchfree box for a further 3 seconds, this ends thermal disinfec-
tion. You hear a beep. Thermal disinfection ends automatically
after 5 minutes. The thermostat must be reset to the normal
temperature immediately after thermal disinfection!
Please refer to the water temperature settings on page 13 for
temperature adjustment.
Dornbracht recommends to conclude a maintenance contract to
ensure the periodic inspection.
100 – 240 V AC
Contains: FCC ID: W8J-SIR13D, IC: 8529A-SIR13D,
50 – 60 Hz
CMIIT ID: 2018AJ7206
12 V DC
5 W
Hereby, Aloys F. Dornbracht GmbH & Co. KG declares that the
IP X4
radio equipment type eSET Touchfree is in compliance with
5 – 35 °C / 41 – 95 °F
Directive 2014/53/EU. The full text of the EU declaration of con-
5,785 – 5,815 MHz
formity is available at the following internet address:
www.dornbracht.com
necessary.
temperature adjustment.
3 sec