GB
13 - The motor M1 stops for a moment and then restarts opening of the gate.
14 - Press the button P/P when the leaf connected to motor M1 is fully open.
15 - The leaf connected to motor M2 starts to open automatically.
16 - Press the button P/P when the leaf connected to motor M2 is fully open.
17 - Allow the desired pause time to elapse before closing.
18 - When the desired pause time has elapsed, press the button P/P; the motor M2 starts to close the gate.
19 - The required interval between closing of the two leaves must be selected during this movement. To set
the delay time, press the button P/P when the leaf connected to motor M2 has reached the point in which
the leaf connected to motor M1 should start moving.
20 - The motor M2 stops for a moment and then restarts closing of the gate.
21 - Press the button P/P when the leaf connected to motor M2 is fully closed.
22 - The leaf with the motor M1 starts to close automatically.
23 - Press the button P/P when the leaf connected to motor M1 is fully closed.
24 - The LED L1 goes out indicating the end of programming.
Type 2
AUTOMATION SYSTEM WITH 2 MOTORS WITH LIMIT SWITCHES or with module MAS200.
54