English
3. Mounting the couplings
The clip-in coupling is made for mounting to stock with socket NEM
362. Exchange the existing coupling for the current transmitting
coupling. After the exchange of the coupling continue with leading the
connection wires into the vehicle.
Only connect accessories in accordance with the manufactures
instructions.
Attention:
!
The mobility of the bogie should not be obstructed by the connection
wires.
Attention:
!
The maximum current per wire is
0.5 A persistent or
1.0 A up to 60 seconds.
If you supply several accessories from one wire, the collective current
should not exceed these values.
4. Check list for troubleshooting
The current transmission via the coupling does not work.
Possible cause: The connection wires are not properly soldered in or
have been torn off. à Check the connections.
Possible cause: The wire bridge of the SK-2 for the current transmission
is deformed. à Adjust the wire bridge carefully.
Page 10
SK-2 | SK-4