Redmond RMC-M110A Manuel De L'utilisateur page 18

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

VII. BEFORE ADDRESSING A SERVICE CENTER
Error Code
Е1
Е3
Е5
Problem
The appliance does not switch on.
The device fails to seal hermetically. Steam escapes
from the rim of the lid.
Dish is taking too long to cook.
The packaging, user manual and the device itself shall be taken to the applicable collection point for the recycling of electrical and electronic
equipment. Do not throw away the electronic waste with household trash to help protect the environment.
© REDMOND. All rights reserved. 2014
Reproduction, transfer, distribution, translation or other reworking of this document or any part thereof without prior written permission of the legal
owner is prohibited.
18
Error Description
Pressure sensor malfunction.
System error; possible control board or heating element
malfunction.
Device is overheated.
Possible Cause
Voltage supply failure.
Sealing ring is missing or improperly positioned.
Sealing ring is dirty.
Sealing ring became deformed.
Voltage supply interruption.
There is a foreign object between the bowl and the
heating element.
The bowl is not properly positioned.
Heating element is dirty.
Error Handling
Unplug the appliance and let it cool down. Close the lid tightly. If this
does not eliminate an error address an authorized service center.
Address an authorized service center.
Unplug the appliance and let it cool down.
Solution
Check the voltage supply.
Position sealing ring properly.
Clean sealing ring.
Replace sealing ring.
Check the voltage supply.
Remove foreign object.
Position the bowl properly.
Unplug the device and let it cool down. Clean heating
element.

Publicité

Table des Matières
loading

Table des Matières