2. Grounded, cord-connected machines intended for use on a supply circuit having a nominal rating less than
150 volts:
If the machine is intended for use on a circuit that has an outlet that looks like the one illustrated in Fig. B, the machine
will have a grounding plug that looks like the plug illustrated in Fig. B. A temporary adapter, which looks like the adapter
illustrated in Fig. C may be used to connect this plug to a matching 2-conductor receptacle as shown in Fig. C, if a
properly grounded outlet is not available. The temporary adapter should be used only until a properly grounded outlet can
be installed by a qualified electrician. The green-colored rigid ear, lug, and the like, extending from the adapter must be
connected to a permanent ground such as a properly grounded outlet box. Whenever the adapter is used, it must be held
in place with a metal screw.
note: In Canada, the use of a temporary adapter is not permitted by the Canadian Electric Code.
SHOCK HAZARD. In all cases, make certain that the receptacle in question is properly grounded. If you
are not sure, have a qualified electrician check the receptacle.
GROUNDED
OUTLET BOX
CURRENT
CARRYING
PRONGS
GROUNDING BLADE
IS LONGEST OF THE 3 BLADES
FIG. B

extenSIon CorDS

Use proper extension cords. Make sure your
extension cord is in good condition and is a 3-wire extension
cord which has a 3-prong grounding type plug and matching
receptacle which will accept the machine's plug. When using an
extension cord, be sure to use one heavy enough to carry the
current of the machine. An undersized cord will cause a drop in
line voltage, resulting in loss of power and overheating. Fig. D
shows the correct gauge to use depending on the cord length. If
in doubt, use the next heavier gauge. The smaller the gauge
number, the heavier the cord.
ForeWorD
DELTA® Model 18-900L 18" (457 mm) Drill Press With Lasers is a heavy-duty machine with a 3/4 HP, 120V induction
motor, 5/8" capacity chuck and key, cast iron table, rack and pinion elevation mechanism, an external depth stop and an
integrated quill stop. The 18-900L has a tilting table for angle drilling. Side edges and parallel slots are provided for fast
workpiece clamping. The laser helps users target the workpiece exactly where the drill bit will enter the material.
notICe: The manual cover illustrates the current production model. All other illustrations contained in the manual are
representative only and may not depict the actual labeling or accessories included. These are intended to illustrate
technique only.

FUnCtIonaL DeSCrIptIon

GROUNDED OUTLET BOX
GROUNDING
MInIMUM GaUGe extenSIon CorD
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES
ampere
rating
Volts
of Cord in Feet
0-6
120
0-6
120
0-6
120
0-6
120
6-10
120
6-10
120
6-10
120
6-10
120
10-12
120
10-12
120
10-12
120
10-12
120
12-16
120
12-16
120
12-16
120
6
MEANS
ADAPTER
FIG.C
total Length
Gauge of
extension Cord
up to 25
18 aWG
25-50
16 aWG
50-100
16 aWG
100-150
14 aWG
up to 25
18 aWG
25-50
16 aWG
50-100
14 aWG
100-150
12 aWG
up to 25
16 aWG
25-50
16 aWG
50-100
14 aWG
100-150
12 aWG
up to 25
14 aWG
25-50
12 aWG
GREATER THAN 50 FEET NOT RECOMMENDED
Fig. D