Technical specifications
The steam generator is equipped with:
•
Aluminium water reservoir
•
Water reservoir volume. 2 litres
•
Acid-proof stainless steel tubular elements
•
Automatic emptying 60 minutes after the steam bath
has been switched off
•
Automatic flushing after emptying
•
2-division output
•
Electronic water level regulation
•
Electronic level protection
•
Acid-proof stainless steel electrodes
•
Continuous steam production
•
Always use the correct power output, regardless of the water
quality and level
•
Built-in temperature cut-out
•
Built-in dirt filter
•
Automation for remote control
•
Rinse-proof design
•
IP class X5
•
Error code clearing
•
Automatic emptying during operation, adjustable
•
Built-in Wi-Fi module 2412-2462 MHz, <20dBm. The product
must be installed and used so as to maintain a minimum
distance of 20 cm from the user.
Pipework installation
To be done by an authorised plumber.
Water connection
Preparatory pipe installation. Always use approved connections
and hoses for fixed installation. Install Stella in Wet ZONE 1
Connect the incoming water using the hoses supplied (1300 mm
long, 1/2")
IMPORTANT!
Before the incoming water supply is
connected to the steam generator, the piping system must be
flushed through. Flushing prevents metal particles and other
impurities entering the steam generator system from the piping.
IMPORTANT!
The incoming water pressure must be
between 1 and 5 bar (min 100kPa and max 500kPa).
It is an advantage to install a shut-off valve in the water supply
line to facilitate repairs/servicing.
3.
cc 90 mm
2.
3.
cc 90 mm
Fig. 4 Connection terminals
1. Hot / Cold water with shut-off option 1/2"
2. Area for electrical wiring
3. Suspension holes
120 mm
1.
795 mm