Télécharger Imprimer la page

Master DHP 45 Mode D'emploi page 7

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
In the "OFF" position the dehumidifier never starts
(unipolar switch).
►5.2.HOUR COUNTER (2): The hour counter indicates
the number of hours of operation of the dehumidifier.
►5.3.VENTILATION
SPEED
ventilation speed selector allows the dehumidifier to
work at the maximum air flow or at an intermediate air
flow depending on the need.
►5.4.ALARM LIGHT (4): The alarm light lights up when,
in case of dehumidifier with tank, the tank is full or the
direct exhaust is clogged up and in case of dehumidifier
with pump (optional), there is a malfunctioning in the
water discharge system. When the warning light comes
on the dehumidifier does not work, reset the appliance
to restart it.
►5.5.REMOTE HUMIDISTAT SOCKET (5): If a remote
humidistat is connected to the socket, the relative
humidity you wish to achieve in the room may be
controlled remotely.
►5.6.VOLTAGE CHANGE SWITCH (6) (where present):
In dual voltage models (...DV), the dehumidifier
operating voltage may be set to suit the voltage
supplied by the electricity mains.
►►6. SWITCH-ON
IMPORTANT: In dual voltage models (...DV), check:
►1-POSITION OF THE VOLTAGE CHANGE SWITCH
(220-240V / 110-120V) (Fig. 5); If the set voltage does
not match that supplied by the mains, the voltage
must be adapted. Loosen the two screws fastening
the cover (Fig. 6), move/press the switch on the
supplied voltage value (Fig. 7) and refit the cover
(Fig. 8).
►2-CHECK THE TYPE OF SOCKET; If the type of
socket does not match the power supply features, a
suitable adapter must be fitted.
IF THE VOLTAGE CHANGE SWITCH POSITION,
THE TYPE OF SOCKET AND THE POWER SUPPLY
ARE CONSISTENT, YOU MAY PROCEED WITH THE
SWITCH ON SEQUENCE.
In order to start up the dehumidifier, it must have
remained in vertical position (normal use position)
for at least eight hours. Failure to comply with
this rule may cause irreparable damage to the
dehumidifier.
►6.1.Follow all the safety instructions;
►6.2.Connect the supply plug to the power mains (Fig. 9)
(SEE VOLTAGE IN THE "TECHNICAL DATA TABLE");
►6.3.Turn the humidistat (1 Fig. 4) on the desired relative
humidity value, the dehumidifier will start automatically.
Thanks to the "VENTILATION SPEED" selector (3 Fig. 4),
the dehumidifier may be operated at the maximum air flow
or at an intermediate air flow depending on the need, in
order to achieve the utmost comfort in the room.
►►7. SWITCH-OFF
Proceed as follows to switch off the dehumidifier:
►7.1.Turn the humidistat (1 Fig. 4) to "OFF";
►7.2.Disconnect the supply plug from the power mains
with dehumidifier off (Fig. 10).
REMOTE HUMIDISTAT CONNECTION
►►8.
For remote humidistat ready models (5 Fig. 4), remove
the cover connected to the dehumidifier and connect
the remote humidistat (optional) (Fig. 11). For correct
dehumidifier operation, completely rotate the knob of the
SELECTOR
(3): The
humidistat on the control panel (1 Fig. 4) to "CONT" and
set the desired humidity on the remote humidistat.
►►9. IF THE DEHUMIDIFIER DOES NOT
START OR DOES NOT DEHUMIDIFY
If the "ALARM LIGHT" (4 Fig. 4) switches on, this means
that the water recovery tank is full and/or there is pump
malfunctioning (optional), just empty the tank and/or
reset the pump. Should the problem persist, contact the
authorised technical service centre.
►►10. CONNECTION TO DISCHARGE PIPING
This dehumidifier allows for the option to directly connect
the appliance to a fixed discharge pipe.
►10.1.IN THE STANDARD CASE OF DEHUMIDIFIER
WITH TANK: The tank has a fitting which may be
connected to a pipe with 16mm internal diameter. Before
connecting the pipe, remove the screw/cover (where
present) (Fig. 12) and check fitting cleanliness, in order
to avoid possible obstructions.
►10.2.IN CASE OF DEHUMIDIFIER WITH PUMP
(OPTIONAL): A water drain pump (optional) may be
installed onto the dehumidifier (Fig. 13). Connection is
easy and straightforward, thanks to the specific electrical
connector and the hydraulic fitting located at the rear,
which can be connected to a pipe with 16mm internal
diameter. Before connecting the pipe, remove the
screw/cover (where present) (Fig. 14) and check fitting
cleanliness, in order to avoid possible obstructions. ALL
INSTRUCTIONS AND DETAILS FOR INSTALLATION
ARE SUPPLIED IN THE PUMP KIT.
►►11. PERIODIC MAINTENANCE
The only maintenance to be performed regularly is
filter cleaning (Fig. 15). Cleaning must be performed by
removing the filter from the front of the dehumidifier (Fig.
16) and placing it under the water tap in an ordinary sink.
This must be performed on average every month; in the
event of use in very dusty environments cleaning must be
more frequent.
Depending on use, cleaning of the finned coil may be
required, with a low pressure water jet. Before performing
washing it is strictly required to disconnect the supply plug
from the power mains (Fig. 10). To perform washing follow
the below steps (Fig. 17-18):
►11.1.Remove the screw that secure the cover to the
dehumidifier (1);
►11.2.Rotate the cover (2);
►11.3.Remove the four screws and remove the protection
from the finned coil (3). (Wash the finned coil with a
low pressure water, paying attention not to wet the
electrical panel. WATER MUST ONLY FLOW FROM
THE TOP DOWN);
►11.4.Install the protection and the two screws (4);
►11.5.Rotate the cover to bring it back to a vertical
position (5);
►11.6.Install the screw than secures the cover to the
dehumidifier (6).
Before restarting the dehumidifier, ensure the electrical
parts are not wet and/or moist, in normal conditions at
least eight hours must elapse. This cleaning operation
improves the dehumidifier performance and assures its
long life.
en
it
de
es
fr
nl
pt
da
fi
no
sv
pl
ru
cs
hu
sl
tr
hr
lt
lv
et
ro
sk
bg
uk
bs
el
zh

Publicité

loading

Ce manuel est également adapté pour:

Dhp 65Dhp 45dvDhp 65dv